SECTION IX

TECHNICAL INFORMATION

The following section contains various technical information important to the service person in servicing and maintaining the dryer.

A. MOTOR PLATE (HIGH and LOW VOLTAGE)

The motor plate is located on the side of the drive motor (see illustration) and contains a graphical representation of the motor wiring for both low and high voltage ratings.

Removing the cap reveals the wiring to the motor. On each wire there is a number which corresponds to the numbers on the motor plate. Depending on whether the dryer is operating on low or high voltage, the wiring should match the motor plate as follows:

The dots and lines represent connections (refer to the illustration above).

For example:

On low voltage - wire no. 14 connected to wire no. 4

-wire no. 1 is connected to wire no. 7, which in turn are both connected to L1 On high voltage - wire no. 14 is insulated or capped

-wire no. 4 is connected to wire no. 7

-wire no. 1 is connected to L1

51

Image 55
Contents ML-82 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section SERVICE/PARTS Information Important Information Safety PrecautionsStandards Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications MLG-82 Gas MLS-82 Steam Component Identification Page Cleaning Routine MaintenanceLubrication AdjustmentsDescription of Parts Control Panel AssemblyDoor Switch Assembly Lint Drawer Lint Drawer SwitchTemperature Sensor Bracket Assembly Basket and Support AssemblyTumbler Bearing Assembly DRIVE/FAN Mount Assembly Idler ARM AssemblyBlower Motor Sail Switch Assembly HSI HOT Surface Ignition Burner BOX AssemblyFront Panel Assembly Reversing Relay Panel Introduction ServicingTo Replace Computer Board To Replace Keyboard Label AssemblyTo Replace Microprocessor Temperature Sensor Probe Computer ControlsHSI Ignitor Flame Sensor Probe Ignition ControlsTo Remove Hot Surface Ignitor To Remove Flame Sensor ProbeTo Replace Gas Valve Refer to burner illustration on To Test and Adjust Gas Water Column PressureTo Replace Main Burner Orifices To Convert Natural Gas to L.P. Gas To Replace HSI Module To Replace Burner TubesTo Replace Burner HI-LIMIT Thermostat GAS Models only Sail Switch Assembly GAS Models only To Adjust Sail Switch To Replace Sail SwitchTo Install New Main Door Glass To Replace Main Door AssemblyTo Replace Main Door Hinge Block To Replace Front PanelTo Replace Steam Coil Damper System Steam Controls InstallationTo Replace Steam Coil To Replace PistonTo Replace The Needle Valve To Replace the 3-Way Micro ValveTo Replace Tumbler Pulley Reversing Tumbler and Bearing AssemblyTo Replace The Rear Tumbler Bearing To Replace Idler Bearing Idler Shaft and Bearing AssemblyTo Replace The Front Tumbler Bearing To Replace Idler PulleyTumbler Basket Drive PulleyTumbler Alignment Vertical To Replace The Tumbler And/Or Tumbler Support Tumbler Alignment LateralBelts Refer to Illustrations in Sections I and K Belt Tension Adjustment-Tumbler To IdlerTo Replace V-Belts Belt Tension Alignment Motor To IdlerDiagnostic L.E.D. Display Failure Codes Phase 6 OPL System DiagnosticsPage E.D. Display Indicator Number E.D. Light Emitting Diode Display IndicatorsPage Fuse Main Fuse Input L.E.D. Indicator FAN Blower Output L.E.D. light emitting diode IndicatorAIR AIR JET Output L.E.D. Indicator Optional HT1 Heat Output L.E.D. IndicatorSail Sail Switch Input L.E.D. Indicator Lint Lint Door Input L.E.D. light emitting diode IndicatorMain Main Door Input L.E.D. Indicator Drum Tumbler HI-LIMIT Input L.E.D. IndicatorPower Supply Input L.E.D. Indicator E.D. Codes GAS only Ignition Attempt Failure Fault CodesGAS Models only Power 24 VAC is not Evident AT GAS Valve GAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT CircuitComputer will not accept keypad touchpad entries TroubleshootingDryer operates but is taking too long to dry Drive motor runs, burner is on, but basket will not turnThermal overload for drive motor is tripping Overload for impellor fan motor is tripping Burner hi-limit safety thermostat is trippingThere is excessive vibration coming from the basket Electrical Troubleshooting Drive motor reverses but does not forward, blower motor runs No Display ConditionLint Door Condition Blower motor does not operate, drive motor runsTemp Sensor Fail Check Main Door ConditionMotor Plate High and LOW Voltage Technical InformationFor example Contact American Dryer Corporation Data LabelAmerican Gas Association, Canadian Gas Association Data Label Model DryerManual Reset HI-LIMIT Instructions Computer Logic Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationReturning Warranty Parts Page ML-82 Tool List ADC 450404 1- 12/21/99-50