D. L.E.D. CODES
1. Display Codes |
|
A | SLOPE FACTOR |
ALL REV | ALWAYS REVERSING |
ANTI WRINKL dELAY TIME | |
ANTI WRINKL GUARd ACTIVE | |
ANTI WRINKL GUARd ON TIME | |
AUTO CYCLE | AUTOMATIC MODE |
b | HEAT LOSS (OFF SET) FACTOR |
bURNER CONTROL FAIL | GAS ONLY POWER (24VAC) IS NOT EVIDENT AT GAS VALVE |
bURNER FLAME FAIL | NO BURNER FLAME SENSED |
bURNER SAFETY FAIL | GAS/ELECTRIC ONLY BURNER/OVEN OPEN |
bUZZ | BUZZER (TONE) |
bUZZ TIME | BUZ TIME |
CEL | DEGREE IN CELSIUS |
CHECK MAIN FUSE | MAIN FUSE FAILURE |
CLEAN LINT | PROMPT TO CLEAN LINT SCREEN, DRYER CYCLE |
COOL | COOL DOWN CYCLE IN PROGRESS |
COOL TIME_M | COOL DOWN TIME |
COOL TEMP_ | COOL DOWN TEMPERATURE |
CYCLEA | PREPROGRAMMED CYCLE A |
CYCLEb | PREPROGRAMMED CYCLE B |
CYCLEC | PREPROGRAMMED CYCLE C |
CYCLED | PREPROGRAMMED CYCLE D |
CYCLEE | PREPROGRAMMED CYCLE E |
CYCLEF | PREPROGRAMMED CYCLE F |
dONE | DRYING or COOLING CYCLE COMPLETE OR DRYER IN |
dRYING | DRYING CYCLE IN PROGRESS |
dRY LEVEL_ | DRYNESS LEVEL (PERCENTAGE OF EXTRACTION) (NUMERICAL VALUE) |
dRY TEMP F_ | DRYING TEMPERATURE |
dRY TIME_M | LENGTH OF DRYING CYCLE |
dRUM SAFETY FAIL | TUMBLER |
ELAPSE TIME_MIN | CYCLE DISPLAY TIME |
ELECTRIC | SPECIFIC HEAT TYPE OR DRYER ELECTRICALLY HEATED |
F | FABRIC TEMPERATURE |
FAR | DEGREE IN FAHRENHEIT |
FLASH | FLASH DISPLAY ACTIVE |
GAS | SPECIFIC HEAT TYPE OF DRYER GAS HEATED |
HOT | INDICATES AN OVERHEAT CONDITION |
LINT dOOR | LINT DRAWER/DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. SWITCH CIRCUIT |
LINT COUNT | DRYING CYCLES RANGE FROM |
_M REMAIN | CYCLE DISPLAY TIME |
MAIN dOOR | DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. DOOR SWITCH CIRCUIT |
MANUAL CYCLE | MANUAL MODE |
MAX ANTI WRINKL GUARd | MAXIMUM GUARD TIME |
NFLASH | FLASH DISPLAY NOT ACTIVE |
NoAIR FLOW | SAIL SWITCH OPEN |
NoANTI WRINKL GUARd | |
NoBUZZ | NO BUZZER (TONE) |
NoHEAT | GAS ONLY IGNITION ATTEMPT FAILURE |
NoREV | NO REVERSE |
NoROTATE SENSOR | NO ROTATIONAL SENSOR SELECTED |
PROGRAM | PROGRAM MODE |
REAdY | NO CYCLE IN PROGRESS |
ROTATE SENSOR ACTIVE | ROTATIONAL SENSOR SELECTED |
ROTATE SENSOR FAIL | ROTATIONAL SENSOR CIRCUIT FAILURE |
_RPM | MONITORS TUMBLER RPM WITH ROTATIONAL SENSOR CIRCUIT ACTIVE |
SAIL SWITCH FAIL | GAS/ELECTRIC ONLY ATTEMPT MADE TO START DRYER WITH SAIL |
| SWITCH DISABLED IN CLOSED POSITION |
SELREV | SELET REVERSE |
SPIN TIME | SPIN TIME |
START GUARd | START ANTI WRINKLE GUARD CYCLE |
STEAM | SPECIFIC HEAT TYPE OR DRYER STEAM HEATED |
STOP TIME | STOP TIME |
TEMP SENSOR FAIL CHECK | FAULT IN M.P. HEAT SENSING CIRCUIT |
TEMP SENSOR FUSE |
|
41