microprocessor controller (computer) determines the ignition control has failed. If this occurs when the cycle is active the machine will display “bURNER CONTROL FAIL.” If the tumbler temperature is above 100º F (38º C) the machine will continue to display “bURNER CONTROL FAIL.” The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). If the tumbler temperature is below 100º (38º C) upon failure the machine will shut down and display “bURNER CONTROL FAIL” with an audio indication.

7.bURNER FLAME FAIL- This routine allows two (2) Flame out retries to occur before proceeding into the error. The count of two (2) will be established every time the call for heat was to occur. Only if it reaches the count of two (2) before the tumbler temperature has reached the set temperature will this error be triggered. The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). If the tumbler temperature is below 100º F (38º C) upon failure, the machine will shut down and display “bURNER FLAME FAIL” with an audio indication. This process will occur every time the heat output is active.

8.MAIN DOOR- This monitors the door circuit. If the machine was not active and the main door was opened the display would ready “REAdY.” If a program attempt was made with the main doors open the display will read “MAIN dOOR” with an audio indication. If the machine is active and the main door was opened the display would read “MAIN dOOR” with no audio indication and the dryer will shut down. Once the main door has closed the display would read “PRESS START” press the “ENTER/ START” key and it will continue the programmed cycle.

9.LINT dOOR- This monitors the lint drawer and door circuit. If the machine was not active and the lint drawer and door was opened the display would read “REAdY.” If a program attempt was made with the lint drawer and door open the display would read “LINT dOOR” with an audio indication. If the machine is active and the lint drawer and door was opened the display would read “LINT dOOR” with no audio indication and the dryer will shut down. Once the lint door was closed the display would read “PRESS START” press the “ENTER/START” key and it will continue the programmed cycle.

10.TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE- This routine monitors the tumbler temperature. When the temperature sensor or fuse opens with the machine not active the display will read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” with an audio indication. If the machine was active at the time that the temperature sensor or fuse opened the display would read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE.” If the tumbler temperature is above 100º F (38º C) the machine will continue to display “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” with an audio indication and run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). If the tumbler temperature is below 100º F (38º C) upon failure the machine will shut down and display “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” with an audio indication. The display will continue to read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” an audio indication will sound for approximately 5 seconds, every 30 seconds until the problem is corrected or the power to the dryer is disconnected (and the problem is corrected).

NOTE: Once the Phase 6 microprocessor controller (computer) detects a problem in the heat circuit, it updates every 30 seconds, so that if the problem was a loose connection in the circuit which corrected itself, the “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” condition would automatically be cancelled and the display will return to “REAdY.”

11.ROTATE SENSOR FAIL- Indicates a rotational sensor circuit failure meaning that there is a fault somewhere in the basket (tumbler) rotating circuit, or the Phase 6 OPL microprocessor controller (com- puter) program related to this circuit (program location 2) is set incorrectly. In the active mode it should be (ROTATE SENSOR ACTIVE), if the dryer is not equipped with the optional rotational sensor it should be set in the nonactive mode (No ROTATE SENSOR).

35

Image 39
Contents ML-82 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section SERVICE/PARTS Information Important Information Safety PrecautionsStandards Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications MLG-82 Gas MLS-82 Steam Component Identification Page Cleaning Routine MaintenanceLubrication AdjustmentsDescription of Parts Control Panel AssemblyDoor Switch Assembly Lint Drawer Lint Drawer SwitchBasket and Support Assembly Temperature Sensor Bracket AssemblyTumbler Bearing Assembly Idler ARM Assembly DRIVE/FAN Mount AssemblyBlower Motor HSI HOT Surface Ignition Burner BOX Assembly Sail Switch AssemblyFront Panel Assembly Reversing Relay Panel Introduction ServicingTo Replace Computer Board To Replace Keyboard Label AssemblyTo Replace Microprocessor Temperature Sensor Probe Computer ControlsHSI Ignitor Flame Sensor Probe Ignition ControlsTo Remove Hot Surface Ignitor To Remove Flame Sensor ProbeTo Test and Adjust Gas Water Column Pressure To Replace Gas Valve Refer to burner illustration onTo Replace Main Burner Orifices To Convert Natural Gas to L.P. Gas To Replace Burner Tubes To Replace HSI ModuleTo Replace Burner HI-LIMIT Thermostat GAS Models only Sail Switch Assembly GAS Models only To Adjust Sail Switch To Replace Sail SwitchTo Install New Main Door Glass To Replace Main Door AssemblyTo Replace Main Door Hinge Block To Replace Front PanelTo Replace Steam Coil Damper System Steam Controls InstallationTo Replace Steam Coil To Replace PistonTo Replace The Needle Valve To Replace the 3-Way Micro ValveTumbler and Bearing Assembly To Replace Tumbler Pulley ReversingTo Replace The Rear Tumbler Bearing To Replace Idler Bearing Idler Shaft and Bearing AssemblyTo Replace The Front Tumbler Bearing To Replace Idler PulleyDrive Pulley Tumbler BasketTumbler Alignment Vertical To Replace The Tumbler And/Or Tumbler Support Tumbler Alignment LateralBelts Refer to Illustrations in Sections I and K Belt Tension Adjustment-Tumbler To IdlerTo Replace V-Belts Belt Tension Alignment Motor To IdlerDiagnostic L.E.D. Display Failure Codes Phase 6 OPL System DiagnosticsPage E.D. Display Indicator Number E.D. Light Emitting Diode Display IndicatorsPage Fuse Main Fuse Input L.E.D. Indicator FAN Blower Output L.E.D. light emitting diode IndicatorAIR AIR JET Output L.E.D. Indicator Optional HT1 Heat Output L.E.D. IndicatorSail Sail Switch Input L.E.D. Indicator Lint Lint Door Input L.E.D. light emitting diode IndicatorMain Main Door Input L.E.D. Indicator Drum Tumbler HI-LIMIT Input L.E.D. IndicatorPower Supply Input L.E.D. Indicator E.D. Codes GAS only Ignition Attempt Failure Fault CodesGAS Models only Power 24 VAC is not Evident AT GAS Valve GAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT CircuitComputer will not accept keypad touchpad entries TroubleshootingDrive motor runs, burner is on, but basket will not turn Dryer operates but is taking too long to dryThermal overload for drive motor is tripping Overload for impellor fan motor is tripping Burner hi-limit safety thermostat is trippingThere is excessive vibration coming from the basket Electrical Troubleshooting Drive motor reverses but does not forward, blower motor runs No Display ConditionLint Door Condition Blower motor does not operate, drive motor runsTemp Sensor Fail Check Main Door ConditionTechnical Information Motor Plate High and LOW VoltageFor example Contact American Dryer Corporation Data LabelAmerican Gas Association, Canadian Gas Association Data Label Model DryerManual Reset HI-LIMIT Instructions Computer Logic SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsReturning Warranty Parts Page ML-82 Tool List ADC 450404 1- 12/21/99-50