American Dryer Corp ADH-170, ADH-120, ADH-75 installation manual Electrical Information

Page 21

Electrical Information _________________

Electrical Requirements

All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, all electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

Important

!Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual

can result in personal injury or component failure.

Note

!Component failure due to improper installation will void the warranty.

Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. Do not use aluminum wire, which could cause a fire hazard. The copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections.

Note

!The use of aluminum wire will void the warranty. An individual ground circuit must be provided to

each dryer, do not daisy chain.

Component failure due to improper voltage application will void the warranty.

The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

Important

!A separate protected circuit must be provided to each dryer.

The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

The wire size must be properly sized to handle the related current.

Warning

!208 VAC and 240 VAC are not the same. Any damage done to dryer components due to

improper voltage connections will automatically void the warranty.

Electrical Service Specifications

Important

!Figures shown are for reversing models only. For non-reversing models contact the factory.

ADSH-75 Steam Models Only

Not available at time of printing. Contact the factory.

ADSH-120 Steam Models Only

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

CIRCUIT

AMP DRAW

VOLTAGE

SERVICE

BREAKER

 

60 Hz

50 Hz

 

 

 

 

208

3

14.5

20

240

3

14.6

20

230

3

17.4

25

380

3

8.5

15

380-400

4*

8.7

15

416

4*

9.0

15

440

3

8.7

15

460/480

3

7.8

15

575

3

5.8

15

* Customer must contact factory to special order 3-wire system. 8/15/07

ADSH-170 Steam Models Only

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

CIRCUIT

AMP DRAW

VOLTAGE

SERVICE

BREAKER

 

60 Hz

50 Hz

 

 

 

 

208

3

28.3

50

240

3

26.7

45

230

3

31.9

50

380

3

16.2

25

380/400

4*

16.1

25

416

4*

16.0

25

440

3

14.4

20

460/480

3

13.9

20

575

3

11.4

20

* Customer must contact factory to special order 3-wire system. 8/15/07

113247 - 3

www.amdry.com

21

Image 21
Contents American Dryer Corporation Installation ManualRetain This Manual in a Safe Place for Future Reference Table of Contents What To Do If You Smell Gas Safety Precautions54.61 cm ADH-75 SpecificationsADEH-75 Hepa Filter Dryer ADH-120 Specifications ADEH-120 Hepa Filter Dryer ADSH-120 Hepa Filter Dryer ADSH-120 Component Identification Front View ADSH-120 Component Identification Rear View 79.69 cm ADH-170 SpecificationsADSH-170 Hepa Filter Dryer ADSH-170 Component Identification Front View ADSH-170 Component Identification Rear View Unpacking/Setting Up Installation ProceduresLocation Requirements Leveling Dryer ADH-75Fresh Air Supply Requirements Dryer Enclosure RequirementsExhaust Requirements Outside Ductwork ProtectionSingle Dryer Venting Vertical Venting Horizontal VentingADH-75 Multiple Dryer Common VentingADH-120 ADH-170Electrical Information ADEH-120 Electric Models Only ADEH-75 Electric Models OnlyADEH-170 Electric Models Only GroundingElectrical Connections Single-Phase 1ø ADSH-75 Only Wiring Connections/HookupSteam Models Only For 110V ApplicationsPhase 3ø Wiring Connections/Hookup For 208-240V ApplicationsElectrically Heated Models Only Steam Information Steam Coil pH LevelSteam Requirements High Pressure Steam Damper System Operation Adjustment ADSH-120 Only Installation InstructionsSteam Damper Air System Connections Air RequirementsSteam Damper System Operation Filter Replacement Hepa Pressure Gauge/Alarm AddendumFilter Information ADH-75, ADH-170Preoperational Test Preparation for Operation/Start-UpPreoperational Instructions Mechanical TimerNon-Coin Models Shutdown InstructionsWarranty Information Service/Parts InformationRoutine Maintenance Data Label Information Procedure for Functional Check Replacement ComponentsManual Reset Burner Hi-Limit Instructions High Temperature AlarmDoor Interlock 113247 ADC Part No 08/15/07

ADH-120, ADH-75, ADH-170 specifications

American Dryer Corp is renowned for its high-quality commercial dryer machines, catering to the needs of various industries, particularly in laundromats, hospitality, and healthcare. Among their extensive lineup, the ADH-170, ADH-75, and ADH-120 stand out for their efficiency, durability, and innovative technology designed to enhance user experience and operational efficiency.

The ADH-170 is a heavy-duty dryer known for its impressive capacity and rapid drying times. With a substantial drum size, it can accommodate large loads, making it ideal for high-traffic commercial environments. This model features advanced moisture sensing technology that automatically adjusts drying times based on the moisture content of the load, ensuring optimal performance while conserving energy. The durable construction and rust-resistant materials also mean that the ADH-170 is built to withstand the rigors of daily use.

The ADH-75 is designed for establishments that require a balance of capacity and efficiency. It offers a slightly smaller drum size compared to the ADH-170 but maintains robust performance characteristics. This model is equipped with an intuitive control panel that allows operators to select various drying cycles and settings, optimizing the dryer’s performance for different fabric types. The ADH-75 also incorporates energy-saving features, such as a cool-down cycle that helps prevent fabric from overheating, thus prolonging garment life.

The ADH-120 is a versatile dryer that strikes an excellent balance between capacity and flexibility. This model comes with an innovative air-flow design, promoting quicker drying times and reducing energy consumption. Its ergonomic design ensures ease of use, while safety features protect operators and users alike. Furthermore, the ADH-120 is outfitted with user-friendly controls that provide programmable settings, making it suitable for various commercial applications.

Overall, the American Dryer Corp ADH series exemplifies a commitment to quality and performance in commercial laundry solutions. From the high-capacity ADH-170 to the efficient ADH-75 and the adaptable ADH-120, each model integrates advanced technology and robust design, making them reliable choices for businesses looking to optimize their laundry operations. With their user-friendly features and energy-efficient solutions, American Dryer Corp continues to set the standard in the commercial dryer market, ensuring customer satisfaction and operational excellence.