American Dryer Corp ADH-120, ADH-170 ADEH-75 Electric Models Only, ADEH-120 Electric Models Only

Page 22

ADEH-75 Electric Models Only

All electrically heated dryers must be connected to the electric service shown on the dryer’s data label. The connecting wires must be properly sized to handle the rated current.

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

 

APPROX.

CIRCUIT

 

AMP DRAW

VOLTAGE

SERVICE

 

BREAKER

 

 

60 Hz

50 Hz

 

 

 

 

 

 

 

30 kW

 

 

 

208

3

 

91

125

230

3

 

83

125

240

3

 

79

100

380

3

 

48

60

380

4*

 

54

70

400

4*

 

51

70

416

4*

 

50

70

460

3

 

40

50

480

3

 

39

50

575

3

 

33

50

 

 

36 kW

 

 

 

208

3

 

108

150

230

3

 

98

125

240

3

 

94

125

380

3

 

58

80

380

4*

 

63

80

400

4*

 

60

80

416

4*

 

58

80

460

3

 

48

60

480

3

 

46

60

* Customer must contact factory to special order 3-wire systems. 8/15/07

ADEH-120 Electric Models Only

All electrically heated dryers must be connected to the electric service shown on the dryer’s data label. The connecting wires must be properly sized to handle the rated current.

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

 

APPROX.

CIRCUIT

 

AMP DRAW

VOLTAGE

SERVICE

 

BREAKER

 

 

60 Hz

50 Hz

 

 

 

 

 

 

 

60 kW

 

 

 

380

4*

 

100

125

416

4*

 

91

125

480

3

 

80

100

600

3

 

64

80

 

 

72 kW

 

 

 

208

3

 

214

300

240

3

 

188

250

230

3

 

198

250

380

3

 

118

150

380

4*

 

118

150

400

4*

 

113

150

416

4*

 

108

150

460

3

 

98

125

480

3

 

94

125

575

3

 

78

100

 

 

75.6 kW

 

 

 

440

3

 

102

150

* Customer must contact factory to special order 3-wire systems. 8/15/07

ADEH-170 Electric Models Only

Available upon request. Contact the factory.

Grounding

A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel.

22

American Dryer Corp.

113247 - 3

Image 22
Contents Installation Manual American Dryer CorporationRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasADH-75 Specifications 54.61 cmADEH-75 Hepa Filter Dryer ADH-120 Specifications ADEH-120 Hepa Filter Dryer ADSH-120 Hepa Filter Dryer ADSH-120 Component Identification Front View ADSH-120 Component Identification Rear View ADH-170 Specifications 79.69 cmADSH-170 Hepa Filter Dryer ADSH-170 Component Identification Front View ADSH-170 Component Identification Rear View Location Requirements Installation ProceduresUnpacking/Setting Up Leveling Dryer ADH-75Dryer Enclosure Requirements Fresh Air Supply RequirementsOutside Ductwork Protection Exhaust RequirementsSingle Dryer Venting Horizontal Venting Vertical VentingADH-120 Multiple Dryer Common VentingADH-75 ADH-170Electrical Information ADEH-170 Electric Models Only ADEH-75 Electric Models OnlyADEH-120 Electric Models Only GroundingSteam Models Only Single-Phase 1ø ADSH-75 Only Wiring Connections/HookupElectrical Connections For 110V ApplicationsFor 208-240V Applications Phase 3ø Wiring Connections/HookupElectrically Heated Models Only Steam Coil pH Level Steam InformationSteam Requirements High Pressure Steam Damper Air System Connections Installation InstructionsSteam Damper System Operation Adjustment ADSH-120 Only Air RequirementsSteam Damper System Operation Filter Information Hepa Pressure Gauge/Alarm AddendumFilter Replacement ADH-75, ADH-170Preparation for Operation/Start-Up Preoperational TestNon-Coin Models Mechanical TimerPreoperational Instructions Shutdown InstructionsService/Parts Information Warranty InformationRoutine Maintenance Procedure for Functional Check Replacement Components Data Label InformationHigh Temperature Alarm Manual Reset Burner Hi-Limit InstructionsDoor Interlock 113247 ADC Part No 08/15/07

ADH-120, ADH-75, ADH-170 specifications

American Dryer Corp is renowned for its high-quality commercial dryer machines, catering to the needs of various industries, particularly in laundromats, hospitality, and healthcare. Among their extensive lineup, the ADH-170, ADH-75, and ADH-120 stand out for their efficiency, durability, and innovative technology designed to enhance user experience and operational efficiency.

The ADH-170 is a heavy-duty dryer known for its impressive capacity and rapid drying times. With a substantial drum size, it can accommodate large loads, making it ideal for high-traffic commercial environments. This model features advanced moisture sensing technology that automatically adjusts drying times based on the moisture content of the load, ensuring optimal performance while conserving energy. The durable construction and rust-resistant materials also mean that the ADH-170 is built to withstand the rigors of daily use.

The ADH-75 is designed for establishments that require a balance of capacity and efficiency. It offers a slightly smaller drum size compared to the ADH-170 but maintains robust performance characteristics. This model is equipped with an intuitive control panel that allows operators to select various drying cycles and settings, optimizing the dryer’s performance for different fabric types. The ADH-75 also incorporates energy-saving features, such as a cool-down cycle that helps prevent fabric from overheating, thus prolonging garment life.

The ADH-120 is a versatile dryer that strikes an excellent balance between capacity and flexibility. This model comes with an innovative air-flow design, promoting quicker drying times and reducing energy consumption. Its ergonomic design ensures ease of use, while safety features protect operators and users alike. Furthermore, the ADH-120 is outfitted with user-friendly controls that provide programmable settings, making it suitable for various commercial applications.

Overall, the American Dryer Corp ADH series exemplifies a commitment to quality and performance in commercial laundry solutions. From the high-capacity ADH-170 to the efficient ADH-75 and the adaptable ADH-120, each model integrates advanced technology and robust design, making them reliable choices for businesses looking to optimize their laundry operations. With their user-friendly features and energy-efficient solutions, American Dryer Corp continues to set the standard in the commercial dryer market, ensuring customer satisfaction and operational excellence.