e.Open main door. The dryer must stop and ALL output indicator lights on the back side of the microprocessor controller (computer) board must go out. (Refer to the illustration on previous page).

f.Try to restart the dryer with the main door open.

g.The microprocessor controller (computer) board’s light emitting diode (L.E.D.) display must read “DOOR.”

h.Close the main door and restart the dryer.

i.Functional check of microprocessor controller (computer) board is complete.

2.For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760) Theory Of Operation:

Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open...as long as there is a call for heat. The DSI module will “LOCKOUT” if the gas burner flame is not sensed at the end of the trial for ignition period. The trial for ignition period will be repeated for a total of three (3) retries/ trials (the initial try and two [2] more retries/trials). If the flame is not sensed at the end of the third retry/ trial (inter-purge period of 30-seconds) the DSI module will “LOCKOUT” (L.E.D. flashes).

A steady L.E.D. indicator indicates normal operation.

No L.E.D. indicator indicates a power or an internal failure has occurred.

46

Image 50
Contents MDG-30 Coin Installation Manual Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASPage Specifications SpecificationsSpecifications GAS only Installation Procedures Unpacking and Setting UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. D Importantventingreminders Electrical Information Electrical RequirementsMust be Provided Single-Phase 1ø Electrical Connections Leads GAS 120GAS Information 22,680 Kcal/hrRating This Pipe Size Requirement Page Preparation for Operation and START-UP Preoperational Tests Preoperational Instructions Basket Tumbler CoatingPage Select Temperature Shutdown Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationDrive motor is not operating does not start TroubleshootingNo light emitting diode L.E.D. display Blower motor is not operating does not start Microprocessor controller computer display reads dSFLMicroprocessor controller computer display reads door No heat, ignitor sparks, burner goes on and off right awayDryer operates but is taking too long to dry Excessive noise or vibration Condensation on main door glassDryer is making scraping noise at basket tumbler area Dryer operates but is taking too long to dry load Heating unit is not operating all temperature selectionsMain burners are burning with a yellow flame Dryer is cycling on hi-limit thermostat Datalabel Information Data LabelSerial Number Procedure for Functional Check Replacement Components Page Page Burner Manual Reset HI-LIMIT Instructions 12/15/99-150