Page 27

2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

 

 

 

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

haded areas are stated in metric equivalents

*Measured at outlet side of gas valve pressure tap when gas valve is on.

b.Gas Connections

Inlet connection ---------- 1/2” N.P.T.

Inlet supply size ---------- 1/2” N.P.T. (minimum) Btu/hr input (per dryer) - 90,000 (22,680 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) of water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) of water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

TYPE OF GAS

 

Liquid

 

 

 

 

 

 

 

 

 

Propane

 

kcal/hr

 

Natural

 

 

Liquid Propane

Btu/hour

 

 

 

Conversion Kit

 

 

 

 

 

 

 

Rating

Rating

Qty.

D.M.S.*

 

Part No.

Qty.

D.M.S.*

Part No.

Part Number

 

 

 

 

 

 

 

 

 

 

90,000

22,680

2

#30

 

140819

2

#46

140806

874050

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#30 =

0.1285” (3.2639 mm).

Liquid Propane Gas

#46 =

0.0810” (2.06 mm).

23

Image 27
Contents MDG-30 Coin Installation Manual Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SpecificationsSpecifications GAS only Unpacking and Setting UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. D Importantventingreminders Electrical Requirements Electrical InformationMust be Provided Single-Phase 1ø Electrical Connections Leads 120 GASGAS Information Kcal/hr Rating22,680 This Pipe Size Requirement Page Preparation for Operation and START-UP Preoperational Tests Basket Tumbler Coating Preoperational InstructionsPage Select Temperature Shutdown Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsWarranty Routine Maintenance CleaningSuggested Cleaning Schedule Lubrication AdjustmentsTroubleshooting No light emitting diode L.E.D. displayDrive motor is not operating does not start Microprocessor controller computer display reads dSFL Blower motor is not operating does not startNo heat, ignitor sparks, burner goes on and off right away Microprocessor controller computer display reads doorDryer operates but is taking too long to dry Condensation on main door glass Dryer is making scraping noise at basket tumbler areaExcessive noise or vibration Heating unit is not operating all temperature selections Main burners are burning with a yellow flameDryer operates but is taking too long to dry load Dryer is cycling on hi-limit thermostat Data Label Datalabel InformationSerial Number Procedure for Functional Check Replacement Components Page Page Burner Manual Reset HI-LIMIT Instructions 12/15/99-150