2.Electrical Service Specifications
ADG-78 II (Gas)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. WHEN ORDERING, SPECIFY EXACT VOLTAGE.
NOTE: A. Fuse ratings are
B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.
C.Circuit breakers for
SERVICE | PHASE | WIRE | APPROX. | MIMIMUM | FUSING | CIRCUIT | |
DUAL ELEMENT | |||||||
VOLTAGE | SERVICE | AMP DRAW | WIRE SIZE* | BREAKER | |||
|
|
|
|
| TIME DELAY |
| |
120 | 1ø | 2 | 13 | #10 | 20 | 25 | |
|
|
|
|
|
|
| |
208 | 1ø | 2 | 8 | #14 | 12 | 15 | |
208 | 3ø | 3 | 5 | #14 | 8 | 15 | |
|
|
|
|
|
|
| |
230 | 1ø | 2 | 7 | #14 | 10 | 15 | |
|
|
|
|
|
|
| |
230 | 3ø | 3 | 5 | #14 | 8 | 15 | |
240 | 1ø | 2 | 7 | #14 | 10 | 15 | |
|
|
|
|
|
|
| |
3ø | 3 | 3 | #14 | 5 | 15 | ||
|
|
|
|
|
|
| |
416 | 3ø | 3 | 3 | #14 | 5 | 15 | |
460 | 3ø | 3 | 3 | #14 | 5 | 15 |
* AWG Stranded Wire ... for individual lenghts less than 100 feet.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the back of the dryer, at the upper right hand corner. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.
20