J. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
1.Turn on electric power to the dryer.
a.Open ALL gas
2.Refer to the Operating Instructions for starting your particular model dryer.
a.Gas Models
1)When the dryer is first started (during initial
NOTE: During the purging period, check to be sure that ALL gas
NOTE: Gas dryers are equipped with a Hot Surface Ignition (HSI) system which has internal diagnostics. If ignition is not established within three times the heat circuit in the HSI module will
2)A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W.C.) pressure is correct and consistent.
NOTE: Water column (W.C.) pressure requirements (measured at the gas valve pressure tap)...
Natural Gas | 3.5 Inches W.C. |
L.P. Gas | 10.5 Inches W.C. |
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.
3.Make a complete operational check of ALL safety related circuits:
a.Door Switch(es)
b.
c.Sail Switch
29