2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

LIQUID PROPANE

 

 

 

 

 

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

 

10.5 inches W.C.

 

26.1 mb

 

 

 

 

 

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

 

27.4 mb

 

 

 

 

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

 

 

 

 

 

* Measured at gas valve pressure tap when gas valve is on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Inlet Size (Each Basket [Tumbler])

 

1/2” F.N.P.T.

 

 

 

 

 

 

 

 

Btu/hr Input (Each Basket [Tumbler])

 

68,000

 

17,136 kcal/hr

 

 

 

 

 

 

Btu/hr Input (Total for Both Baskets [Tumblers])

136,000

 

34,272 kcal/hr

 

 

 

 

 

 

 

 

 

 

 

F.N.P.T. = Female National Pipe Thread

b.Natural Gas

Regulation is controlled by each gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

c.Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

113203-3

Maytag

21

Image 25
Contents MLG31PCB Installation Manual MLG31PCB For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Safety PrecautionsStandard GAS SpecificationsSpecifications GAS only UNPACKING/SETTING UP Installation ProceduresLocation of the Dryer Maytag 113203-3 Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Maytag 113203-3 Maytag Maytag 113203-3 Maytag Maytag 113203-3 Maytag Electrical Requirements Electrical InformationElectrical Service Specifications PER Pocket GAS only GAS Information Type of GAS Typical GAS Connections Maytag Maytag 113203-3 Preoperational Tests Preparation for OperationMaytag 113203-3 Basket Tumbler Coating Shutdown Instructions Operating Instructions Coin ModePause Mode Free ModeRPM Clearing CREDIT/CLEARING Cycle Accessing Coin VaultWrinkle Guard Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceSuggested Cleaning Schedule Lubrication AdjustmentsData Label Information Keyboard Touch PAD Layout Procedure for Functional Check Replacement ComponentsMaytag 113203-3 Optional Gas Piping Kit 03/15/05-14