American Dryer Corp MLG31PCB installation manual Maytag 113203-3

Page 30

4) The dryer will continue through the drying and cooling cycles until the time vended has expired.

NOTE: The dryer can be stopped at any time by opening the main loading door or pressing the pause key. To restart the dryer, press appropriate temperature selection key.

5)Upon completion of the drying and cooling cycles, the buzzer will sound, and the dryer will go into the Anti-Wrinkle mode for 99 minutes, or until the main door is opened.

IMPORTANT: For complete operation details for the computer system refer to the user’s manual included with the dryer.

b.FREE Dry Mode

1)The liquid crystal display (L.C.D.) screen reads “Select Temperature.”

2)Select temperature by pressing “HIGH,” “MEDIUM,” or “LOW.” The cycle/dryer will start and the display will read cycle time.

3)The dryer will continue through the drying and cooling cycles until the drying time and cooling time has expired.

NOTE: The dryer can be stopped at any time by opening the main loading door or pressing the pause key. To restart the dryer, press appropriate temperature selection key.

4)Upon completion of the drying and cooling cycles, the buzzer will sound, and the dryer will go into the Anti-Wrinkle mode for 99 minutes, or until the main door is opened.

IMPORTANT: For complete operation details for the computer system refer to the user’s manual included with the dryer.

3.Heat Circuit Operational Test Gas Models

When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.

The dryer is equipped with a Direct Spark Ignition (DSI) system, which has internal diagnostics. If ignition is not established after three (3) attempts, the heat circuit DSI module will lock out until it is manually reset. To reset the DSI system, open and close the main door and restart the dryer (press desired temperature selection).

NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.

Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each dryer to ensure that the water column (W.C.) pressure is correct and consistent.

26

Maytag

113203-3

Image 30
Contents MLG31PCB Installation Manual MLG31PCB For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Safety Precautions SectionStandard Specifications GASSpecifications GAS only Installation Procedures UNPACKING/SETTING UPLocation of the Dryer Maytag 113203-3 Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Maytag 113203-3 Maytag Maytag 113203-3 Maytag Maytag 113203-3 Maytag Electrical Information Electrical RequirementsElectrical Service Specifications PER Pocket GAS only GAS Information Type of GAS Typical GAS Connections Maytag Maytag 113203-3 Preparation for Operation Preoperational TestsMaytag 113203-3 Basket Tumbler Coating Shutdown Instructions Coin Mode Operating InstructionsFree Mode Pause ModeRPM Accessing Coin Vault Clearing CREDIT/CLEARING CycleWrinkle Guard SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsWarranty Routine Maintenance CleaningSuggested Cleaning Schedule Adjustments LubricationData Label Information Procedure for Functional Check Replacement Components Keyboard Touch PAD LayoutMaytag 113203-3 Optional Gas Piping Kit 03/15/05-14