NOTE: Water column (W.C.) pressure requirements (measured at the gas valve pressure tap):
Natural Gas | 3.5 Inches (8.7 mb) Water Column. |
Liquid Propane (L.P.) Gas | 10.5 Inches (26.1 mb) Water Column. |
IMPORTANT: THERE IS NO REGULATOR PROVIDED IN AN L.P. DRYER. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
4.Make a complete operational check of ALL
5.Each basket (tumbler) should be operated through one (1) complete cycle to ensure that no further adjustments are necessary and that ALL components are functioning properly.
NOTE: The sail switch can be checked for proper operation by opening the control door while the dryer is running and the heating unit (burner) is active (on). The heating unit should shut off within a few seconds. If not, make the necessary adjustments.
BASKET (TUMBLER) COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove this coating.
NOTE: Drying and cooling cycles are complete when the light emitting diode (L.E.D.) display reads “donE.”
6.Computer Programs/Selections:
Each Dual Microprocessor Controller (DMC) computer has been preprogrammed by the factory with the most commonly used program (parameter) selections. If microprocessor controller (computer) program changes are required, refer to the Dual Microprocessor Controller (DMC) Programming Manual, which was shipped with the dryer.