American Dryer Corp MLG31PCB installation manual Free Mode, Pause Mode, Rpm

Page 34

B.FREE MODE

1.When the controller is in the ready state and no cycle is in progress, the liquid crystal display (L.C.D.) screen will display “SELECT TEMP TO START”.

2.Select temperature by pressing “HI” , “MED” , or “LO” . The cycle will start and the controller will display the Dry Cycle selected and the remaining time.

3.The dryer will continue through the drying and cooling cycles, until the drying time has expired.

4.Upon completion of the drying and cooling cycles, the buzzer will sound, and the dryer will go into Wrinkle Guard mode for 99 minutes or until the door has been opened.

5.HOT KEYS – In free mode, the HOT KEYS are always enabled. The HOT KEYS are as follows: Pressing and holding the “HI” key will show the remaining dry time available.

Pressing and holding the “MED” key will show the temperature readings of the exhaust probe. The exhaust probe temperature reading is displayed on the left. If the dryer is an axial model, the temperature reading of the axial temperature transducer will also be displayed, this will be the middle temperature reading.

Pressing and holding the “LO” key will show the RPMs of the basket (tumbler).

The “PAUSE” key will pause the dryer. If the dryer is paused, pressing the “HI” , “MED” , or “LO” key will restart the dryer into the appropriate drying cycle. Once the dry cycle has started again, the HOT KEYS will be enabled again.

C.PAUSE MODE

If the “PAUSE” key is pressed and the door is not opened, the dryer will restart in 20-seconds. If the “PAUSE” key is pressed and the dryer door is opened and left open, the dryer will wait for the pause time defined in PL01 to expire. Once the pause time expires, the controller will begin to count down the dry time. If the dryer door is opened without first pressing the “PAUSE” key the controller will continue to count down the dry time.

D. RPM

The Phase 7 dual microprocessor controller (computer) also displays the basket (tumbler) RPM by pressing and

holding the “LO” key while the basket (tumbler) is rotating (the basket [tumbler] must be rotating for approximately 30-seconds before getting a true RPM reading). In coin mode, the program switch must be in the “UP” position.

30

Maytag

113203-3

Image 34
Contents MLG31PCB Installation Manual MLG31PCB For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Safety Precautions SectionStandard Specifications GASSpecifications GAS only UNPACKING/SETTING UP Installation ProceduresLocation of the Dryer Maytag 113203-3 Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Maytag 113203-3 Maytag Maytag 113203-3 Maytag Maytag 113203-3 Maytag Electrical Information Electrical RequirementsElectrical Service Specifications PER Pocket GAS only GAS Information Type of GAS Typical GAS Connections Maytag Maytag 113203-3 Preparation for Operation Preoperational TestsMaytag 113203-3 Basket Tumbler Coating Shutdown Instructions Coin Mode Operating InstructionsPause Mode Free ModeRPM Clearing CREDIT/CLEARING Cycle Accessing Coin VaultWrinkle Guard Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceSuggested Cleaning Schedule Adjustments LubricationData Label Information Procedure for Functional Check Replacement Components Keyboard Touch PAD LayoutMaytag 113203-3 Optional Gas Piping Kit 03/15/05-14