B. Electric Models Only
MLE-75 (Electric)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE: A. Fuse ratings are
B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.
C . Circuit breakers for 3Ø dryers must be
KW
20
24
30
33
36
40
AMP DRAW
APPROX.
APPLIED VOLTAGE/PHASE
208/1ø (60 Hz) | 240/1ø (50/60 Hz) | 208/3ø (50/60 Hz) | 240/3ø (50/60 Hz) | 380/3ø (50 Hz) | 416/3ø (50 Hz) | 460/3ø (60 Hz) |
105 | 90 | 33 | ||||
72 | 63 | 36 | 33 | |||
88 | 77 | 45 | 41 | |||
53 | ||||||
104 | 92 | 53 | 48 | |||
59 | ||||||
|
|
|
|
|
|
|
IMPORTANT: Figures shown are for
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the back side of the upper/top control door. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.
IMPORTANT: 3 phase figures shown are for a 3 wire service ONLY.