American Dryer Corp MLG31PCA installation manual Type of GAS

Page 26

2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at gas valve pressure tap when gas valve is on. W.C. = Water column in inches.

M LG31PCA

Gas Inlet Size (each basket/tumbler)

 

1/2” N.P.T.

 

 

 

 

Btu/hr Input (each basket/tumbler)

68,000

 

17,136 kcal/hr

 

 

 

 

Btu/hr Input (total for both baskets/tumblers)

136,000

 

34,272 kcal/hr

 

 

 

 

N.P.T. = National Pipe Thread

 

 

 

b.Natural Gas

Regulation is controlled by each gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column pressure.

c.Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

22

Image 26
Contents MLG31PCA Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASPage Specifications 71-1/2Gas Location of the Dryer Installation ProceduresUNPACKING/SETTING UP Page Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Page Electrical Information Electrical RequirementsLG31PCA GAS Information Type of GAS Typical GAS Connections Page Page Preparation for Operation Preoperational TestsPage Basket Tumbler Coating Shut Down Instructions Operating Instructions Starting the DryerPage Page Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationTroubleshooting SectionviiiFailed motor contactor/relay DMC computer L.E.D. display reads dSFL Failed keyboard touch pad label assembly Failed DMC computer If the dryer is equipped with optional battery back-up Dryer operates, but is taking too long to dry Condensation on main door glass Procedure for Functional Check Replacement Components Page Optional Gas Piping Kit Part No 1 02/11/02-20 05/01/02-250