American Dryer Corp AD-200 PHASE 7 service manual Createapotentialsafetyhazard

Page 44

C. NATURAL GAS and L.P. (Liquid Propane) GAS CONVERSION INSTRUCTIONS

IMPORTANT: CONVERSION MUST BE PERFORMED BY COMPETENT TECHNICIANS IN ACCORDANCE WITH LOCAL and STATE CODES.

NOTE: Converting the dryer to L.P. Gas disables the internal regulator of the gas valve, therefore, an external regulator must be provided at the source of the L.P. gas supply (L.P. tank) or the dryer. The water column (W.C.) gas pressure must be regulated is 10.5 inches (26.1 mb) for safe and efficient dryer operation. Low, inconsistent, or too high a gas pressure will result in improper operation of the dryer’s heat and safety circuits. POOR EFFICIENCY CAN

CREATEAPOTENTIALSAFETYHAZARD.

1.Discontinue electrical power to the dryer.

2.Close ALL gas shut-off valves in the dryer’s gas supply line. Turn the gas cock dial to the off position on the gas valve.

3.Disconnect the gas valve wiring.

Be sure to identify the correct location of each wire for correct reinstallation.

4.Disconnect union connection in the gas supply line.

IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be used.

5.Loosen and remove the screws from the brackets holding the gas valve/manifold assembly to the burner box.

6.Remove the gas valve and manifold assembly from the dryer.

7.Unscrew the main burner orifices and replace them with the L.P. orifices provided.

NOTE: Use extreme care when handling (removing or replacing) orifices. THESE ORIFICES ARE

MADE OF BRASS and CAN BE EASILY DAMAGED.

8.Remove the two (2) screws on the gas valve regulator. Remove the regulator and the gasket.

9.Install the new gasket and L.P. regulator. Replace the two (2) screws.

NOTE: USE ONLY NEW PARTS PROVIDED.

10.Place the L.P. conversion labels on the gas valve.

11.Reverse the procedure for reinstalling the gas valve/manifold assembly to the dryer.

4 0

Image 44
Contents AD-200 Phase Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Components AD-200 Reference Guide Base Section Section Explosion could ResultStandards Cleaning LiquidsAT 80 PSI 5.51 Bars Empty the compressed air filter bowlLubrication Adjustments Days After Installation and Every 6 Months ThereafterSpecifications and Dimensions Dimensions Obligation Obligation Installation Requirements ENCLOSURE/AIR SUPPLY/EXHAUST RequirementsOperational Service Check Procedure Electrical and GAS RequirementsHeat Section Direct Spark Ignition DSI System COMPONENTS/FUNCTIONSVAC Direct Spark Ignition DSI Module 225º F 107º C Thermostat Redundant Gas Valve Troubleshooting Flow Chart Quick Reference First Visual CheckSecond Visual Check Third Visual Check Troubleshooting the Direct Spark Ignition DSI System DSI Ignitor GAP Feeler GaugePage Page Three Visual Checks First Visual Check Second Visual Check Third Visual Check With a Flame System Diagnosis Gas PressureDSI Ignitor/Flame-Probe Assembly Adjustments ContinuouslyPage Page Direct Spark Ignition DSI 24 VAC Transformer With a Flame Light RED Continuously Page Page Direct Spark Ignition DSI 24 VAC Transformer Createapotentialsafetyhazard Discontinue electrical power to the dryerSteam Coil System Operation Open ALL gas shut-off valves closed in Step #2Page Page Disconnect compressed air supply from the dryer Page Description Of Components Resistive Temperature Device RTD Sprinkler System DescriptionSprinkler System Operation Page HP 2.24 kw Control Relay Replacement Supplies Before Servicing the DryerPage Page Tilting System Description Tilting Solenoid Valve Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Page Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page FILTER/REGULATOR Assembly Filter Maintenance To remove filter elementDoor Systems OperationManual Doors Pneumatic Automatic Door Replacement or Removal Automatic DoorsPage Page Loosen the cord grip cap that the valve wire go through Control and Electrical System Ladder Diagram Page Button does not Disable the High Voltage to the Dryer Drive tumbler and basket MotorPage ºC + ºC + ºK PLC Programmable Logic Controller Page Page Page Discontinue electrical power to the dryer Page Page Page Tumbler Basket System Reinstall V-belts then tighten turnbuckle Important do not Overtighten TurnbuckleImportant do not Overtighten Turnbuckle Page Page Important do not Overtighten Turnbuckle Page Page Page Phase 7 OPL System Diagnostics FAN Contactor Fault The Fan Contactor was not pulled RSS Rear Sail SwitchFnol Fan Overload Rbhl Rear Burner High LimitBoard Input Description Red L.E.D Then the L.E.D. is onIs OFF Down, then the L.E.D. is on24VM RED L.E.D Control voltage at the spare inputs Valve is open ON, then the L.E.D. is onProgrammable and Defaulted to Front Door Open Programmable and Defaulted to Front Door ClosedProgrammable and Defaulted to Lint Drawer Programmable and Defaulted to Front DownProgrammable and Defaulted to Rear Down Programmable and Defaulted to Rear Door OpenProgrammable and Defaulted to Rear Door Closed Programmable and Defaulted to SpareTroubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 105 106 Dryer operates but is taking too long to dry Excessive noise and vibration 109 Procedure for Functional Check Replacement Components 111 ADC450039 1- 04/21/00-25

AD-200 PHASE 7 specifications

American Dryer Corp (ADC) has long been a leader in the laundry equipment industry, and its AD-200 PHASE 7 model is a testament to the company's commitment to innovation and efficiency. Designed for commercial applications, the AD-200 PHASE 7 is a high-performance dryer that sets a new standard for drying technology in laundromats, hotels, and other laundry facilities.

One of the standout features of the AD-200 PHASE 7 is its advanced drying system that utilizes a powerful, high-efficiency motor. This motor works in conjunction with a unique airflow design, ensuring that clothes dry quickly and evenly while minimizing energy consumption. The dryer is built to handle large loads, making it an ideal choice for busy commercial environments where efficiency is crucial.

The AD-200 PHASE 7 incorporates state-of-the-art technology to optimize the drying process. It features a microprocessor control system that allows operators to customize drying cycles based on the specific needs of different fabrics. This system not only enhances the user experience by providing precise control but also helps protect garments from over-drying and damage. Additionally, the dryer boasts multiple temperature settings, allowing users to choose the best drying conditions for each load.

Another key characteristic of the AD-200 PHASE 7 is its durable construction. Built with high-quality materials, including reinforced stainless steel, this dryer is designed to withstand the rigors of daily use in a commercial setting. Its robust design not only extends the lifespan of the equipment but also reduces the need for frequent maintenance, which can be a significant cost-saving benefit for businesses.

Energy efficiency is another aspect where the AD-200 PHASE 7 excels. It is equipped with an efficient heat exchange system that recycles hot air during the drying process, reducing energy consumption without compromising performance. This feature contributes to lower utility bills, making it a more sustainable option for businesses looking to improve their environmental footprint.

In conclusion, the American Dryer Corp AD-200 PHASE 7 is a powerful, efficient, and durable commercial dryer that meets the demands of high-volume laundry operations. With its advanced technological features, customizable controls, and energy-saving capabilities, the AD-200 PHASE 7 not only enhances operational efficiency but also provides excellent value for commercial laundry providers. Businesses looking to invest in reliable drying solutions will find the AD-200 PHASE 7 an outstanding choice.