American Dryer Corp AD-120ES II installation manual Installation Procedures, Location Requirements

Page 14

SECTION III

INSTALLATION PROCEDURES

Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).

A. LOCATION REQUIREMENTS

Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).

1.The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.

IMPORTANT: “The dryer must be installed on noncombustible floors only.”

2.The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

3.The dryer is for use in noncombustible locations.

4.Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements in Section D).

5.Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

6.Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

7.Dryer must be exhausted to the outdoors as noted in this manual (refer to Exhaust Requirements Section E).

8.Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.

9.The dryer must be installed with a proper exhaust duct connection to the outside.

10.The dryer must be installed with provisions for adequate combustion and make-up air supply.

10

Image 14
Contents AD-120ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Cleaning Adjustments Lubrication Data LabelImportant Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification Specifications ADG-120ES ADE-120ES ADS-120ES Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Downstream of Dryer Page Page Page Electrical Information Electrical Service Specifications PER Dryer ADE-120 II 72 Kw Electric Reversing, 3ø ADE-120 II 80 Kw Electric Reversing, 3ø Page Page GAS Information Type of GAS Page Page 689.47 kPa Steam Information862.84 kPa 204 kg/hrPage Bars Page Preparation for Operation Preoperational Tests Inches 26.1 mb water column Shut Down Instructions Basket CoatingOperating Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Suggested Cleaning Schedule Routine MaintenanceCleaning Steam Dryers Adjustments LubricationTroubleshooting Drive motor is not operating does not startBlower motor is not operating does not start Microprocessor controller computer display reads dSFL Microprocessor controller computer display reads doorFailed 24 VAC transformer No heat for Steam Models only No heat for Electric Models onlyDryer operates but is taking too long to dry Condensation on main door glassDryer is making scraping noise at basket tumbler area Excessive noise and/or vibrationDrive motor only is not operating does not start GAS ModelsElectric Models Dryer operates but is taking too long to dry load Failed hi-limit thermostat for GAS and Electric Models onlyCondensation on main door glass Data Label Information Data LabelSerial Number Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page Page P O R T a N T ADC P/N114501 ADC 02/07/01-25 02/12/01-25 04/06/01-25 06/27/01-25