ADE-120 II (80 Kw Electric)
Reversing, 3ø
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local or National Electrical Codes to listed appliance amp draw data.
B.Circuit breakers are
C.Circuit breakers for
OVEN SIZE | SERVICE |
| WIRE | APPROX. | ||
PHASE | AMP DRAW | |||||
(Kw) | VOLTAGE | SERVICE | ||||
| 60 Hz | 50 Hz | ||||
|
|
|
| |||
80 | 208 | 3ø | 3 | 234 | ||
80 | 240 | 3ø | 3 | 205 | 209 | |
|
|
|
|
|
| |
80 | 3ø | 3 | 130 | |||
|
|
|
|
|
| |
80 | 3ø | 4 | 130 | |||
|
|
|
|
|
| |
80 | 416 | 3ø | 3 | 120 | ||
80 | 416 | 3ø | 4 | 120 | ||
|
|
|
|
|
| |
80 | 460/480 | 3ø | 3 | 107 | ||
|
|
|
|
|
| |
80 | 575/600 | 3ø | 3 | 86 | ||
|
|
|
|
|
|
NOTE: ADC has discontinued making 80 Kw dryers. This information is for dryers in the field.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.