C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of twelve (12) inches above the dryer's outer top; except along the front of the dryer which may be closed if desired.

NOTE: Allowances must be made for opening the control door.

X = 12" minimum, 24" suggested for ease of maintenance.

NOTE: Air considerations are important for proper and efficient operation.

Dryers may be positioned side wall to side wall. However, a 1/16" minimum allowance must be made for opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about two (2) feet away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back guard). Refer to the illustration above for details.

10

Image 14
Contents MDG-30 Fast Dry Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Technical Information Section Safety Precautions Personal Injury or Fire could ResultGAS Supply Before ANY Covers or Guards are Removed ADJUSTING, INSTALLATION, or Testing Ofany Equipment perOsha Occupational Safety and HealthAdministration Standards Specifications SuperSpecifications MDG-30 Fast Dry Installation Procedures Location Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Importantventingreminders Electrical Information Electrical RequirementsMust be Provided Odfn Klwh Uhhq Important a Circuit Serving Each Dryer Must be Provided DG-30 Fast DRY GAS GAS Information Injury and Improper Operation of the Dryer$785$ Page Page Preparation for Operation and START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Page OPL Models Shut Down Instructions Service PartsReturning Warranty Cards SectionRoutine Maintenance CleaningAdjustments LubricationNo L.E.D. light emitting diode display Drive motor not operating does not startBlower motor not operating does not start Microprocessor computer display reads dSFLMicroprocessor controller computer display reads door No heat, ignitor sparks, burner goes on and off right awayDryer operates but is taking too long to dry Excessive noise or vibration Condensation on main door glassDryer or scraping noise at basket tumbler area Dryer operates but is taking too long to dry load Heating unit not operating ALL temperature selectionsMain burners are burning with a yellow flame Dryer is cycling on hi-limit thermostat Technical Information Data LabelSerial Number Procedure for Functional Check Replacement Components Direct Spark Ignition DSI System MAYTAG-113069 1-01/29/99-250