Maytag MDG-30 manual Main burners are burning with a yellow flame

Page 46

S.Main burners are burning with a yellow flame

1.Burner air shutters are out of adjustment.

2.Insufficient makeup air.

3.Dust or lint in burner.

4.Insufficient gas pressure.

MECHANICAL COIN MODELS

A.Heating unit not operating (ALL temperature selections)

1.Fault in sail switch circuit

a.Sail switch out of adjustment or failed.

b.Sail switch not closing or fluttering

1)Check blower (impellor/fan) motor and rotation direction.

2)Restriction in location exhaust system.

2.Failed burner hi-limit circuit.

3.Failed lint compartment automatic (225º F [107º C]) safety thermostat circuit.

4.Failed heat selector switch.

B.Heat unit not operating for only one (1) temperature selection

1.Failed thermostat corresponding to selection made.

2.Failed heat selector switch

C.Dryer operates but is taking too long to dry load

1.Heating unit cycling on hi-limit thermostat

2.Housekeeping

a.Lint screen and lint compartment not being cleaned on a regular basis.

b.Lint accumulation in location exhaust system.

3.Insufficient makeup air.

4.Failed hi-limit thermostat

5.Failed lint compartment automatic (225º F [107º C]) safety thermostat circuit.

6.Extractors not performing properly.

7.Low or inconsistent gas pressure

42

Image 46
Contents MDG-30 Fast Dry Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Technical Information Section Safety Precautions Personal Injury or Fire could ResultOsha Occupational Safety and HealthAdministration Standards ADJUSTING, INSTALLATION, or Testing Ofany Equipment perGAS Supply Before ANY Covers or Guards are Removed Specifications SuperSpecifications MDG-30 Fast Dry Installation Procedures Location Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Importantventingreminders Electrical Information Electrical RequirementsMust be Provided Odfn Klwh Uhhq Important a Circuit Serving Each Dryer Must be Provided DG-30 Fast DRY GAS GAS Information Injury and Improper Operation of the Dryer$785$ Page Page Preparation for Operation and START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Page OPL Models Shut Down Instructions Service PartsReturning Warranty Cards SectionRoutine Maintenance CleaningAdjustments LubricationNo L.E.D. light emitting diode display Drive motor not operating does not startBlower motor not operating does not start Microprocessor computer display reads dSFLMicroprocessor controller computer display reads door No heat, ignitor sparks, burner goes on and off right awayDryer operates but is taking too long to dry Dryer or scraping noise at basket tumbler area Condensation on main door glassExcessive noise or vibration Main burners are burning with a yellow flame Heating unit not operating ALL temperature selectionsDryer operates but is taking too long to dry load Dryer is cycling on hi-limit thermostat Technical Information Data LabelSerial Number Procedure for Functional Check Replacement Components Direct Spark Ignition DSI System MAYTAG-113069 1-01/29/99-250