MULTIPLE DRYER (Common) VENTING

HORIZONTAL VENTING

If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of the airflow. No more than four

(4) dryers should be connected to one (1) main common duct run.

The main common duct may be any shape so long as the minimum cross-sectional area is provided. The main duct should be tapered with the diameter increasing before each individual 10-inch duct is added (refer to Illus. C and Illus. D).

Illus. C

Horizontal venting must not exceed 20 feet - this calculation compensates for the use of a maximum of only one (1) elbow which is the outside outlet protection.

NOTE: Distance between dryer single ducts being connected to the main common duct must be a minimum of 31-3/8" (dryer width).

Duct work should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rear service panels or guards.

15

Image 19
Contents MDG-30 Fast Dry Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Technical Information Section Personal Injury or Fire could Result Safety PrecautionsOsha Occupational Safety and HealthAdministration Standards ADJUSTING, INSTALLATION, or Testing Ofany Equipment perGAS Supply Before ANY Covers or Guards are Removed Super SpecificationsSpecifications MDG-30 Fast Dry Installation Procedures Location Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Importantventingreminders Electrical Requirements Electrical InformationMust be Provided Odfn Klwh Uhhq Important a Circuit Serving Each Dryer Must be Provided DG-30 Fast DRY GAS Injury and Improper Operation of the Dryer GAS Information$785$ Page Page Preparation for Operation and START-UP GAS Models only Preoperational TestsPreoperational Instructions Page OPL Models Shut Down Instructions Parts ServiceSection Returning Warranty CardsCleaning Routine MaintenanceLubrication AdjustmentsDrive motor not operating does not start No L.E.D. light emitting diode displayMicroprocessor computer display reads dSFL Blower motor not operating does not startNo heat, ignitor sparks, burner goes on and off right away Microprocessor controller computer display reads doorDryer operates but is taking too long to dry Dryer or scraping noise at basket tumbler area Condensation on main door glassExcessive noise or vibration Main burners are burning with a yellow flame Heating unit not operating ALL temperature selectionsDryer operates but is taking too long to dry load Dryer is cycling on hi-limit thermostat Data Label Technical InformationSerial Number Procedure for Functional Check Replacement Components Direct Spark Ignition DSI System MAYTAG-113069 1-01/29/99-250