Maytag Vent System Chart

Number of

Type

Box/louvered

Angled

90° elbows

of vent

hoods

hoods

 

 

 

 

0

Rigid metal

100 ft. (30.5 m)

94 ft. (28.7 m)

 

 

 

 

1

Rigid metal

90 ft. (27.4 m)

84 ft. (25.6 m)

 

 

 

 

2

Rigid metal

80 ft. (24.4 m)

74 ft. (22.6 m)

 

 

 

 

3

Rigid metal

71 ft. (21.6 m)

65 ft. (19.8 m)

 

 

 

 

4

Rigid metal

63 ft. (19.2 m)

57 ft. (17.4 m)

 

 

 

 

NOTE: Bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the charts.

INSTALL VENT SYSTEM

1. Install exhaust hood

12" min.

(305 mm)

12" min. (305 mm)

Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.

2. Connect vent to exhaust hood

Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.

CONNECT INLET HOSES

For non-steam models, skip to “Connect Vent.”

The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.

1. Turn cold water off, remove and replace rubber washer

Turn cold water faucet off and remove washer inlet hose.

Check and see if rubber washer is in the “Y” connector. Remove old rubber washer from inlet hose and replace with new rubber washer provided.

2. Attach short hose and “Y” connector

Fig. A

Fig. B

If space permits, attach the female end of the “Y” connector to the cold water faucet. See figure A.

If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. See figure B. Attach short hose to cold water faucet. Screw on coupling by hand until

it is seated on faucet. Then attach “Y” connector to male end of the short hose. Screw on coupling by hand until it is seated on connector.

3.

Tighten couplings

Using pliers, tighten the couplings with additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

15

Image 15
Contents Electric Dryer Installation Instructions Dryer Safety Parts supplied steam models Installation RequirementsTools needed Parts supplied all modelsYou will need Location RequirementsElectrical Requirements If your outlet looks like this Install Leveling LegsIf connecting by direct wire Prepare dryer for leveling legsChoose electrical connection type Attach power supply cord strain reliefAttach power supply cord to strain relief Electrical ConnectionConnect remaining wires Connect neutral ground wire and neutral wireConnect ground wire Prepare to connect neutral ground wire and neutral wireRemove center screw Connect neutral wireAttach direct wire strain relief Direct Wire Strain ReliefPrepare your 4-wire cable for direct connection Wire Direct Wire ConnectionIf your wiring looks like this Optional 3-wire Connection Prepare your 3-wire cable for direct connectionConnect external ground wire VentingRigid metal vent Plan Vent System Determine vent path Whirlpool Vent System ChartAlternate installations for close clearances Special provisions for mobile homesConnect Inlet Hoses Install Vent SystemCheck for leaks Attach long hose to Y connector and tighten couplingsAttach long hose to dryer fill valve and tighten coupling Turn on cold water faucetMove dryer to final location Adjust leveling legsConnect Vent Level DryerSteam models only Complete Installation ChecklistRemove the door assembly Reverse Door SwingReverse the strike Reinstall the door2013 05/13 All rights reserved