Maytag W10562339B-SP, W10562335B Venting, Connect external ground wire, Rigid metal vent

Page 12

2. Connect neutral ground wire and neutral wire

B

E

C

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw.

3. Connect remaining wires

Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws.

4. Connect external ground wire

A

G

Connect a separate copper ground wire (G) from the external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.”

VENTING

VENTING REQUIREMENTS

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

4"

(102 mm)

4" (102 mm) heavy metal exhaust vent

■■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

■■ Do not use plastic or metal foil vent.

Rigid metal vent:

■■ Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location.

■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 73/4 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review Vent System Chart and if necessary, modify existing vent system to achieve best drying performance.

12

Image 12
Contents Electric Dryer Installation Instructions Dryer Safety Installation Requirements Tools neededParts supplied all models Parts supplied steam modelsLocation Requirements You will needElectrical Requirements Install Leveling Legs If connecting by direct wirePrepare dryer for leveling legs If your outlet looks like thisAttach power supply cord strain relief Attach power supply cord to strain reliefElectrical Connection Choose electrical connection typeConnect neutral ground wire and neutral wire Connect ground wirePrepare to connect neutral ground wire and neutral wire Connect remaining wiresConnect neutral wire Attach direct wire strain reliefDirect Wire Strain Relief Remove center screwPrepare your 4-wire cable for direct connection Wire Direct Wire ConnectionIf your wiring looks like this Prepare your 3-wire cable for direct connection Optional 3-wire ConnectionConnect external ground wire VentingRigid metal vent Plan Vent System Whirlpool Vent System Chart Alternate installations for close clearancesSpecial provisions for mobile homes Determine vent pathInstall Vent System Connect Inlet HosesAttach long hose to Y connector and tighten couplings Attach long hose to dryer fill valve and tighten couplingTurn on cold water faucet Check for leaksAdjust leveling legs Connect VentLevel Dryer Move dryer to final locationComplete Installation Checklist Remove the door assemblyReverse Door Swing Steam models onlyReinstall the door Reverse the strike2013 05/13 All rights reserved