Maytag W10562335B Remove center screw, Connect neutral wire, Attach direct wire strain relief

Page 9

3-wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

3. Connect remaining wires

3-wire receptacle (NEMA

3-prong plug

type 10-30R)

Connect remaining wires to outer terminal block screws.

 

Tighten screws. Finally, reinsert tab of terminal block cover

 

into slot of dryer rear panel. Secure cover with hold-down

 

screw. Now, go to “Venting Requirements.”

 

DIRECT WIRE CONNECTION

Spade terminals with

Ring terminals

upturned ends

 

1. Remove center screw

B

Remove center terminal block screw (B).

2. Connect neutral wire

B

C

Connect neutral wire (white or center) (C) of power supply cord to center terminal block screw (B). Tighten screw.

Direct Wire Strain Relief

1. Attach direct wire strain relief

A

B

C

Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief

(C)through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads.

9

Image 9
Contents Electric Dryer Installation Instructions Dryer Safety Tools needed Installation RequirementsParts supplied all models Parts supplied steam modelsYou will need Location RequirementsElectrical Requirements If connecting by direct wire Install Leveling LegsPrepare dryer for leveling legs If your outlet looks like thisAttach power supply cord to strain relief Attach power supply cord strain reliefElectrical Connection Choose electrical connection typeConnect ground wire Connect neutral ground wire and neutral wirePrepare to connect neutral ground wire and neutral wire Connect remaining wiresAttach direct wire strain relief Connect neutral wireDirect Wire Strain Relief Remove center screwPrepare your 4-wire cable for direct connection Wire Direct Wire ConnectionIf your wiring looks like this Optional 3-wire Connection Prepare your 3-wire cable for direct connectionConnect external ground wire VentingRigid metal vent Plan Vent System Alternate installations for close clearances Whirlpool Vent System ChartSpecial provisions for mobile homes Determine vent pathConnect Inlet Hoses Install Vent SystemAttach long hose to dryer fill valve and tighten coupling Attach long hose to Y connector and tighten couplingsTurn on cold water faucet Check for leaksConnect Vent Adjust leveling legsLevel Dryer Move dryer to final locationRemove the door assembly Complete Installation ChecklistReverse Door Swing Steam models onlyReverse the strike Reinstall the door2013 05/13 All rights reserved