Maytag W10150608A, W10150609A manual If this is a new vent system Vent material

Page 15

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used.

4"

10.2 cm

4" (10.2 cm) heavy metal exhaust vent

Vent products can be purchased from your dealer or by calling Maytag Services. For more information, see the “Assistance or Service” section.

Rigid metal vent

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Elbows

45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape.

Clamp

Exhaust

Recommended hood styles are shown here.

B

A

4"

(10.2 cm)

4" (10.2 cm)

A. Louvered hood style

B. Box hood style

The angled hood style (shown here) is acceptable.

4"

(10.2 cm)

2½" (6.4 cm)

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

15

Image 15 Contents
W10150608A Sécheuse ÉlectriqueTable DES Matières Table of ContentsYour safety and the safety of others are very important Dryer SafetyInstallation Instructions Tools and PartsLocation Requirements Mobile home installations require Installation ClearancesMobile Home Additional Installation Requirements Dryer DimensionsElectrical Requirements U.S.A. Only It is your responsibilityElectrical Connection Grounding Instructions Electrical Requirements Canada OnlyPower Supply Cord Direct Wire Style 1 Power supply cord strain reliefElectrical Connection U.S.A. Only Style 2 Direct wire strain relief Wire connection Power Supply Cord Wire connection Direct Wire BDE CG F 5cm Optional 3-wire connection If using an existing vent systemVenting Requirements If this is a new vent system Vent material Plan Vent System Special provisions for mobile home installationsDetermine vent path Install Vent SystemInstall Leveling Legs Vent system chartConnect Vent Level DryerReverse Door Swing Optional If the dryer will not start, check the following Complete InstallationU.S.A CanadaStarting Your Dryer Dryer USEDryer Care Cleaning the Dryer LocationCleaning the Lint Screen Every Load CleaningChanging the Drum Light Cleaning the Dryer InteriorRemoving Accumulated Lint Vacation and Moving CareTroubleshooting Dryer OperationDryer Results Loads are wrinkled Cycle time too shortLint on load Stains on load or drumCanada Assistance or ServiceAccessories U.S.AONE Year Limited Warranty Maytag Corporation Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA SécheusePièces nécessaires Instructions DinstallationOutillage et pièces Pièces fourniesExigences d’emplacement On a besoin deDégagements de séparation à respecter ’installation dans une maison mobile exige Spécifications électriques’est à l’utilisateur qu’incombe la responsabilité de Exigences concernant lévacuation En cas dutilisation du système dévacuation existantEn cas de nouveau système dévacuation Planification du système d’évacuation Brides de serrageÉvacuation Déterminer litinéraire dacheminement du conduit Autres installations où le dégagement est réduitMise à niveau de la sécheuse Installation du système d’évacuationInstallation des pieds de nivellement Raccordement du conduit d’évacuationSi la sécheuse ne démarre pas, vérifier ce qui suit Achever l’installationMise en marche de la sécheuse Utilisation DE LA SécheusePour arrêter la sécheuse Option grille de séchageFonctionnement du programme de séchage automatique Arrêt et remise en marcheNettoyage de l’intérieur de la sécheuse Nettoyage de lemplacement de la sécheuseEntretien DE LA Sécheuse Nettoyage du filtre à charpieFonctionnement de la sécheuse DépannageDéménagement Changement de l’ampoule du tambourLa minuterie ne progresse pas visiblement Résultats de la sécheuseCharges froissées Temps de programme trop courtCharpie sur la charge Taches sur la charge ou sur le tambourSi vous avez besoin de pièces de rechange Assistance OU ServiceAccessoires Au CanadaGarantie DES Gros Appareils Ménagers Maytag Corporation Tous droits réservés W10150608A SP PN W10150609A