Maytag W10150608A, W10150609A manual Complete Installation, U.S.A, Canada

Page 19

6.Be certain to keep cardboard spacer centered between doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed.

7.Attach door hinges to dryer door so that the larger hole is at the bottom of the hinge.

8.Remove door strike (E) from cabinet. Use a small, flat-blade screwdriver to gently remove 4 hinge hole plugs (F) on left side of cabinet. Insert plugs into hinge holes on right side of cabinet.

9.Insert screws into bottom holes on left side of cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.

10.Remove door strike plug (B). Insert the door strike you removed in Step 8 into hole and secure with screw. Insert door strike plug into original door strike hole and secure with screw.

11.Close door and check that door strike aligns with door catch (C). If it is needed, slide door catch left or right within slot to adjust alignment.

Complete Installation

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all of your tools.

3.Dispose of/recycle all packaging materials.

4.Check the dryer’s final location. Be sure the vent is not crushed or kinked.

5.Check that the dryer is level. See “Level Dryer.”

6.In the U.S.A.

For power supply cord installation, plug into an outlet. For direct wire installation, turn on power.

In Canada

Plug into a grounded 4 prong outlet. Turn on power.

7.Remove any protective film on the console and any tape remaining on the dryer.

8.Read “Dryer Use.”

9.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.

10.Set the dryer on a full heat cycle (not an air cycle) for 20 minutes and start the dryer.

If the dryer will not start, check the following:

Controls are set in a running or “On” position.

Start button has been pushed firmly.

Dryer is plugged into an outlet and/or electrical supply is on.

Household fuse is intact and tight, or circuit breaker has not tripped.

Dryer door is closed.

11.When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.

If you do not feel heat, turn off the dryer and check the following:

There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.

NOTE: You may notice a burning odor when the dryer is first heated. This odor is common when the heating element is first used. The odor will go away.

19

Image 19 Contents
W10150608A Sécheuse ÉlectriqueTable DES Matières Table of ContentsYour safety and the safety of others are very important Dryer SafetyTools and Parts Installation InstructionsLocation Requirements Mobile home installations require Installation ClearancesMobile Home Additional Installation Requirements Dryer DimensionsIt is your responsibility Electrical Requirements U.S.A. OnlyElectrical Connection Grounding Instructions Electrical Requirements Canada OnlyStyle 1 Power supply cord strain relief Power Supply Cord Direct WireElectrical Connection U.S.A. Only Style 2 Direct wire strain relief Wire connection Power Supply Cord Wire connection Direct Wire BDE CG F 5cm If using an existing vent system Optional 3-wire connectionVenting Requirements If this is a new vent system Vent material Plan Vent System Special provisions for mobile home installationsDetermine vent path Install Vent SystemInstall Leveling Legs Vent system chartLevel Dryer Connect VentReverse Door Swing Optional If the dryer will not start, check the following Complete InstallationU.S.A CanadaStarting Your Dryer Dryer USEDryer Care Cleaning the Dryer LocationCleaning the Lint Screen Every Load CleaningChanging the Drum Light Cleaning the Dryer InteriorRemoving Accumulated Lint Vacation and Moving CareDryer Operation TroubleshootingDryer Results Loads are wrinkled Cycle time too shortLint on load Stains on load or drumCanada Assistance or ServiceAccessories U.S.AONE Year Limited Warranty Maytag Corporation Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA SécheusePièces nécessaires Instructions DinstallationOutillage et pièces Pièces fourniesOn a besoin de Exigences d’emplacementDégagements de séparation à respecter Spécifications électriques ’installation dans une maison mobile exige’est à l’utilisateur qu’incombe la responsabilité de En cas dutilisation du système dévacuation existant Exigences concernant lévacuationEn cas de nouveau système dévacuation Brides de serrage Planification du système d’évacuationÉvacuation Déterminer litinéraire dacheminement du conduit Autres installations où le dégagement est réduitMise à niveau de la sécheuse Installation du système d’évacuationInstallation des pieds de nivellement Raccordement du conduit d’évacuationSi la sécheuse ne démarre pas, vérifier ce qui suit Achever l’installationMise en marche de la sécheuse Utilisation DE LA SécheusePour arrêter la sécheuse Option grille de séchageFonctionnement du programme de séchage automatique Arrêt et remise en marcheNettoyage de l’intérieur de la sécheuse Nettoyage de lemplacement de la sécheuseEntretien DE LA Sécheuse Nettoyage du filtre à charpieFonctionnement de la sécheuse DépannageDéménagement Changement de l’ampoule du tambourLa minuterie ne progresse pas visiblement Résultats de la sécheuseCharges froissées Temps de programme trop courtCharpie sur la charge Taches sur la charge ou sur le tambourSi vous avez besoin de pièces de rechange Assistance OU ServiceAccessoires Au CanadaGarantie DES Gros Appareils Ménagers Maytag Corporation Tous droits réservés W10150608A SP PN W10150609A