4-wire connection: Direct Wire
IMPORTANT: A
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5"
(12.7 cm). Cut 1¹⁄₂" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.
1" .5cm) (2
5" | |
(12.7 | cm) |
|
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1. Remove center
2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
A B
C
E
D
A.External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center
B.Center
C.Neutral wire (white or center wire)
D.¾" (1.9 cm) UL listed strain relief
E.Neutral ground wire
11