Maytag W10131619A Optional 3-wire connection, Tighten strain relief screw

Page 12

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.

6.You have completed your electrical connections. Now go to “Venting Requirements.”

1.Loosen or remove center silver-colored terminal block screw.

2.Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

B C

D

AE

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.

A B C

D

E

F

A. Neutral ground wire

B. External ground conductor screw

C. Center silver-colored terminal block screw

D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

3.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

4.Tighten strain relief screw.

A. External ground conductor screw

B. Neutral ground wire

C. Center silver-colored terminal block screw

D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

F. Grounding path determined by a qualified electrician

3.Connect the other wires to outer terminal block screws. Tighten screws.

12

Image 12
Contents Electric Dryer W10131619ATable of Contents Dryer SafetyImportant Safety Instructions Installation Instructions Tools and PartsLocation Requirements Mobile Home Additional Installation Requirements Electrical RequirementsIt is your responsibility Electrical ConnectionIf using a power supply cord If connecting by direct wireGauge solid copper wire do not use aluminum If your outlet looks like thisPower Supply Cord Direct Wire Style 1 Power supply cord strain reliefInstall strain relief Electrical ConnectionStyle 2 Direct wire strain relief Wire connection Power Supply Cord Wire connection Direct Wire CG F Loosen or remove center silver-colored terminal block screwOptional 3-wire connection Tighten strain relief screwIf using an existing vent system Venting RequirementsIf this is a new vent system Vent material Plan Vent System ExhaustRecommended hood styles are shown here Angled hood style shown here is acceptableInstall Vent System Alternate installations for close clearancesSpecial provisions for mobile home installations Vent system chartInstall Leveling Legs Connect VentLevel Dryer Reverse Door Swing OptionalComplete Installation If the dryer will not start, check the followingDryer USE Starting Your DryerHow Automatic Drying Works Stopping and RestartingCleaning the Dryer Location Cleaning the Lint ScreenDryer Care Drying Rack OptionCleaning the Dryer Interior Removing Accumulated LintVacation and Moving Care Troubleshooting Dryer OperationDryer Results Lint on load Stains on load or drumLoads are wrinkled Cycle time too shortAssistance or Service AccessoriesEnhance your dryer with these premium accessories Part Number AccessoryW10131619A