Maytag W10131619A Plan Vent System, Exhaust, Recommended hood styles are shown here

Page 14

Exhaust

Recommended hood styles are shown here.

B

A

4"

(102 mm)

4" (102 mm)

A. Louvered hood style

B. Box hood style

The angled hood style (shown here) is acceptable.

4"

(102 mm)

2½" (63.5 mm)

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

 

B

 

C

 

D

A

E

 

F

 

G

 

B

 

H

A. Dryer

E. Clamps

B. Elbow

F. Rigid metal or flexible metal vent

C. Wall

G. Vent length necessary to connect elbows

D. Exhaust hood

H. Exhaust outlet

Standard exhaust installation with rigid metal or flexible metal vent

14

Image 14
Contents Electric Dryer W10131619ATable of Contents Dryer SafetyImportant Safety Instructions Location Requirements Installation InstructionsTools and Parts It is your responsibility Mobile Home Additional Installation RequirementsElectrical Requirements Electrical ConnectionGauge solid copper wire do not use aluminum If using a power supply cordIf connecting by direct wire If your outlet looks like thisInstall strain relief Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Electrical ConnectionStyle 2 Direct wire strain relief Wire connection Power Supply Cord Wire connection Direct Wire CG F Loosen or remove center silver-colored terminal block screwOptional 3-wire connection Tighten strain relief screwIf this is a new vent system Vent material If using an existing vent systemVenting Requirements Recommended hood styles are shown here Plan Vent SystemExhaust Angled hood style shown here is acceptableSpecial provisions for mobile home installations Install Vent SystemAlternate installations for close clearances Vent system chartLevel Dryer Install Leveling LegsConnect Vent Reverse Door Swing OptionalComplete Installation If the dryer will not start, check the followingHow Automatic Drying Works Dryer USEStarting Your Dryer Stopping and RestartingDryer Care Cleaning the Dryer LocationCleaning the Lint Screen Drying Rack OptionVacation and Moving Care Cleaning the Dryer InteriorRemoving Accumulated Lint Dryer Results TroubleshootingDryer Operation Loads are wrinkled Lint on loadStains on load or drum Cycle time too shortEnhance your dryer with these premium accessories Assistance or ServiceAccessories Part Number AccessoryW10131619A