4-wire connection: Power Supply Cord
IMPORTANT: A
BF
A
C D EG
A.
B.
C.Ground prong
D.Neutral prong
E. Spade terminals with upturned ends F. ¾" (19 mm) UL listed strain relief
G.Ring terminals
1.Remove center
2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center,
A B C
E
D
A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center
B. Center
D. ¾" (19 mm) UL listed strain relief E. Neutral ground wire
3.Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
A B C
F E
D
A. External ground conductor screw
B. Center
C. Neutral wire (white or center wire)
D. ¾" (19 mm) UL listed strain relief
E. Ground wire (green or bare) of power supply cord
F. Neutral ground wire
4.Connect the other wires to outer terminal block screws. Tighten screws.
5.Tighten strain relief screws.
6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.
7.You have completed your electrical connections. Now go to “Venting Requirements.”