Electrical Connection
Power Supply Cord |
| Direct Wire |
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Neutral wire (white or center wire) must be connected to center silver terminal.
Ground wire (green or bare wire) must be connected to green ground connector.
Remaining 2 supply wires must be connected to remaining 2 gold terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Neutral wire (white or center wire) must be connected to center silver terminal.
Ground wire (green or bare wire) must be connected to green ground connector.
Remaining 2 supply wires must be connected to remaining 2 gold terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
1.Disconnect power.
2.Remove the
A B C D
A. Terminal block cover
B. External ground conductor screw
C. Center,
D.
E | E. Neutral ground wire | |
F. Hole below terminal block opening | ||
F | ||
|
Style 1: Power supply cord strain relief
■Remove the screws from a ¾" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.
A
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
3.Install strain relief.
7