Humminbird 595C manual Lower Range, Chart Speed, Bottom View

Page 21

FF595_Man_531385-1_A_PrfE.qxd 12/9/2004 2:41 PM Page 40

Lower Range

Lower Range sets the deepest depth range that will be displayed. Automatic is the default setting. When in automatic mode, the lower range will be adjusted by the unit to follow the bottom. Selecting a specific setting locks the depth range into Manual mode. Use both Upper and Lower Range together to view a specific depth range manually when looking

for fish or bottom structure. M will be displayed in the lower right corner of the screen when you start manually adjusting the Lower Range to indicate that you are in Manual mode.

For example, if you are fishing in 60 feet of water but are only interested in the first 30 feet (surface to a depth of 30 feet) you should set the Lower Depth Range limit to 30. The display will show the 0 to 30 foot range, allowing you to see a more detailed view than you would see if the display went all the way to the bottom.

NOTE: A minimum distance of 10 feet will be maintained between the Upper and Lower Range regardless of the manual settings entered.

To adjust the Lower Range:

1.Highlight Lower Range on the Sonar X-Press™ Menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Lower Range setting. (AUTO, 10 to 1000 feet, 3 to 330 meters [International Models Only], Default = AUTO)

Chart Speed

Chart Speed determines the speed at which the sonar information moves across the display, and consequently the amount of detail shown. A faster speed shows more information in the Sonar Views and is preferred by most anglers; however, the sonar information moves across the display quickly. A slower speed keeps the information on the display longer, but the bottom and fish details become compressed and may be difficult to interpret. Regardless of the Chart Speed setting, the RTS® Window will update at the maximum rate possible for the depth conditions. Adjust Chart Speed to your personal preference.

To adjust the Chart Speed:

1.Highlight Chart Speed on the Sonar X-Press™ Menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Chart Speed setting. (1-9, Ultra, where 1 = Slow, 9 = Fast, Ultra = Fastest, Default = 4)

Bottom View

Bottom View selects the method used to represent bottom and structure on the display. Structure ID® represents weak returns in blue and strong returns in red. WhiteLine® highlights the strongest sonar returns in white resulting in a distinctive outline. This has the benefit of clearly defining the bottom on the display. See Bottom Presentation for more information.

To adjust the Bottom View:

1.Highlight Bottom View on the Sonar X-Press™ Menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Bottom View setting. (Structure ID, WhiteLine, Default = Structure ID)

34

35

Image 21
Contents FishFinder 595c Operations Manual Thank You Table of ContentsAlarms Menu Tab Powering Up the Unit Menu System Start-Up Options MenuSetup Menu Tab Sonar X-Press Menu Sonar Views OnlyViews Menu Tab Troubleshooting How Sonar WorksSingle Beam Sonar Multi-Media Card MMC How GPS and Cartography WorkWhat’s On the Sonar Display KHz Fish SymbolHigh Sonar Intensity Return Bait Ball RTS Real Time Sonar Window Low Sonar Intensity ReturnViews Sonar Zoom View Chart View Big Digits ViewSonar View Sonar viewsUnderstanding Sonar History Real Time Sonar RTS WindowBottom Presentation Sonar Zoom View Big Digits ViewBig Digits View Chart View with Active Cursor Chart ViewBird’s Eye View Bird’s Eye ViewCombo View View OrientationViewing Cartography Waypoints, Routes and Tracks Introduction to NavigationSave, Edit, or Delete a Waypoint Waypoints, Routes and TracksChart View with Target Add a Waypoint Target or Trolling GridNavigate to a Waypoint or Position Chart View with Grid Save, Edit or Delete a RouteSave or Clear a Current Track Edit, Delete or Hide Saved Tracks POWER/LIGHT KeyKey Functions View KeyMark Key WAY Cursor Control KeyGoto Key Zoom +/- KeyMain Menu System Normal User Mode Powering Up the UnitSonar Tab, Normal Mode Sonar Tab, Advanced Mode Menu SystemNormal Operation Start-Up Options MenuSimulator System StatusGPS Diagnostic View Position ErrorSonar X-Press Menu Sonar Views OnlyTo adjust the Upper Range To adjust the SensitivitySensitivity Upper RangeChart Speed Lower RangeBottom View Save Current Track Navigation X-Press MenuClear Current Track Save Current RouteSkip Next Waypoint Cancel NavigationRemove Target Remove GridSonar Menu Tab Fish ID+To turn Fish ID+ on or off Fish Sensitivity Depth LinesAdvanced Noise Filter Surface ClutterMax Depth Water TypeTracks Navigation Menu TabWaypoints Tracks Submenu contains the following menu choicesChart Detail Level RoutesMap Borders Spot Soundings Lat/Lon GridShaded Depth North ReferenceSet Simulation Position Map DatumSet Map Offset Clear Map OffsetDepth Alarm Alarms Menu TabFish ID Alarm Low Battery AlarmOff Course Alarm Temp AlarmArrival Alarm Drift AlarmSetup Menu Tab Alarm ToneTo change the Alarm Tone setting Setup tab is selectedUnits Depth User ModeUnits Speed Units TempRestore Defaults Triplog ResetSelect Readouts Advanced, Sonar View OnlyTemp Offset Depth OffsetSpeed Calibration Local Time ZoneDate Format Time FormatNmea Output SonarFishFinder Doesn’t Power Up TroubleshootingFishFinder Defaults to Simulator with a Transducer Attached Views Menu TabProblem Possible Cause Display ProblemsFinding the Cause of Noise IsolationSpecifications Humminbird FishFinder AccessoriesContact Humminbird