Honeywell TE821W user manual Battery Cover, Assembly

Page 9

H. BATTERY COVER

Secures battery compartment on the anemometer base

Assembly

Slide the wind cups on to the anemometer rotating shaft. Do not use force.

Insert the longer arm of the Allen Wrench (provided) into the wind cup set screw opening. Feel the head of the set screw inside the wind cups and tighten carefully the set screw securing the wind cups to the rotating shaft.

Test to ensure cups are securely fastened to the shaft and cannot be removed

Battery installation

Remove four (4) screws from the battery compartment with a small Phillips screwdriver.

Open the battery compartment and install 2 “AA” size alkaline batteries (not included) matching the polarities shown.

Do not close battery compartment yet as you need to make sure that the anemometer sends the signal to the main unit (0.0 mph will appear on the main unit’s wind window if the signal was sent and received successfully)

Aligning

This procedure must be performed after main unit has been powered and all remote weather sensors were received successfully.

Manually point the wind direction vane to the north (use a compass or map if necessary).

Press the “SET” button located inside battery compartment (on the shorter side) with a paper clip. “SET” button selects a new direction for NORTH and, when pressed repeatedly, alternates between the factory default NORTH and user selected NORTH.

Watch for the next anemometer data transmission in the main unit’s wind window – the direction will be updated

Replace the battery compartment door and secure the screws.

Note: Repeat this procedure every time after changing the batteries.

Mounting

Mount the anemometer onto a vertical surface, using the fittings provided.

Placement tips:

The anemometer should be mounted in an open area with a free air flow; away from the nearby trees, buildings or other structures.

For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area.

9

Image 9
Contents Honeywell Appendix City Codes Specifications Table of ContentsInstallation Standard Package ContentsIntroduction Before you beginThermo-Hygrometer Sensor TS33C FeaturesBattery installation Placement tipsMounting Rain Gauge TS906 Anemometer wind sensor TS805 Wind Vane Assembly Battery CoverTime Main UnitWeather DisplayAvoid placing the main unit in the following areas Buttons and Controls Selects the next available window counter-clockwise Initial Set up Clock and Alarms Window Clock and Calendar DisplaysOperation and Window Selection Initial Settings City, Time, Date and Language Selecting Clock and Alarm WindowPressure and Weather Forecast Window Custom Weather Station SettingsSelect Pressure and Weather Forecast Window Changing or Setting Sea Level PressurePressure and Altitude Information Changing Pressure and Altitude ParametersViewing the Pressure, Temperature and Humidity Bar Charts Changing or Setting AltitudeViewing the Moon Phase History Viewing the Sea Level Pressure HistoryMoon Phase Diagram Weather Forecast Displays Viewing Temperature and Humidity for each Channel Temperature and Humidity WindowTemperature and Dew Point Displays Channel Auto-Scan DisplayTemperature Alarm Temperature in Celsius or FahrenheitProgramming Upper and Lower limits for Temperature Alarm Disabling Temperature Alarm levelsSetting Rain Display inches or mm Rainfall Memory ResetSetting up Daily Rainfall Alert Selecting Rain WindowSetting Wind Speed in km/h, mph, m/s or knots Configuring Wind DisplayDisabling the Daily Rainfall Alert Wind WindowEnable/Disable Time Alarms Resetting the Wind Statistics MemoryEnabling or Disabling the Wind Alerts Wind Alert programmingDisable/Enable Snooze function Programming Time AlarmsDisable alarms Atomic Time ReceptionMemory Reset Procedure Remote Sensor StatusActivate Search for Remote Sensors Troubleshooting MaintenanceWeather forecast is inaccurate Appendix City CodesPage Specifications Battery life alkaline Power 12 AA Batteries includedWind Direction Wind SpeedDimensions Weight without batteriesDeclaration of Conformity