Delta DO 9704 manual Order Codes

Page 58

ENGLISH

ORDER CODES

DO 9704 K Pressure gauge - thermometer - data logger kit composed of a diplomatic carrying case, instrument DO 9704, series of fittings, 1 CPA 8-pole din 45326 connecting cable between instrument and probe, manual, 9 Vdc alkaline battery.

NOTE: The pressure or temperature probes must be ordered separately to suit the customer’s requirements.

TP 870 Immersion temperature probe, Pt100 sensor, diam. 3 x 230 mm, measuring range -50°C...+400°C.

TP 870/C Contact temperature probe, Pt100 sensor, diam. 4 x 230 mm, measuring range -50°C...+400°C.

TP 870/P Penetration temperature probe, Pt100 sensor, diam. 4 x 150 mm, measuring range -50°C...+400°C.

TP 870/A Air temperature probe, Pt100 sensor, diam. 4 x 230 mm, measuring range -50°C...+300°C.

Pressure probes: contact surface with Allumina pressurised fluid, stainless steel body AISI 304, male threaded coupling 1/4” BSP, 8-pole DIN 45326 male connector.

TP 704-200MBGI

Pressure probe, full scale 200 mbar relative.

TP 704-500MBGI

Pressure probe, full scale 500 mbar relative.

TP 704-1BGI

Pressure probe, full scale 1 bar relative.

TP 704-2BGI

Pressure probe, full scale 2 bar relative.

TP 704-10BGI

Pressure probe, full scale 10 bar relative.

TP 704-20BGI

Pressure probe, full scale 20 bar relative.

TP 704-50BGI

Pressure probe, full scale 50 bar relative.

TP 704-2BAI

Pressure probe, full scale 2 bar absolute.

TP 704-10BAI

Pressure probe, full scale 10 bar absolute.

TP 704-20BAI

Pressure probe, full scale 20 bar absolute.

TP 704-50BAI

Pressure probe, full scale 50 bar absolute.

TP 704-100BAI

Pressure probe, full scale 100 bar absolute.

TP 704-200BAI

Pressure probe, full scale 200 bar absolute.

TP 704-500BAI

Pressure probe, full scale 500 bar absolute.

TP 704-1000BAI

Pressure probe, full scale 1000 bar absolute.

The probes in the series TP 705 are suitable for measuring the low pressure of non-corrosi- ve gases and dry air, fitting diam. 5 mm.

TP 705-10MBD

Pressure probe, full scale 10 mbar relative.

TP 705-20MBD

Pressure probe, full scale 20 mbar relative.

TP 705-50MBD

Pressure probe, full scale 50 mbar relative.

TP 705-100MBD

Pressure probe, full scale 100 mbar relative.

TP 705-200MBD

Pressure probe, full scale 200 mbar relative.

TP 705-500MBD

Pressure probe, full scale 500 mbar relative.

122

Image 58
Contents Instructions Manual Page Pressure and Temperature DATA-LOGGER English Introduction Keyboard KEY NumbersNumbers Function DescriptionSimbols LIT Besides RELTom of the display Simbols LIT Besides Function Numbers DescriptionSerial Output 300 Baud P0+Press the Prog key to move on to step P1 600 BaudP1+ = data dump Hours minutes Seconds P1+Storage This parameter is used for the fol- lowing two functionsFunction P3+ P4+ = set yearP5+ = set month P6+ = set day P7+ = set hours P8+ = set minutes P9+ Self cut-outP10 P10+To stop storage, press the Enter key Complete printing Reduced printingData Call P11+P11 + Start-StopKEY Simbols LIT Besides Operating modeWhen this operative Ches itself off againIf the battery symbol does not fla Simbols LIT Besides Function Numbers Description EnterMore than 30,000 acquisitions Restart itAfter having taken note HOW to Measure Probe ConnectionVarious operations Temperature Measurement Method of Using the Instrument and WarningsFUL Instrument Signals and MalfunctionsErr LOULOW Battery Warning and Battery Replacement Storage of the Instrument Serial Interface RS 232CType of terminal Command Type ReplyParity None Bit Stop bit Protocol Xon/Xoff Dumping data from the memoryMemory clear Diagram do PrinterExample of a Report Printed by the Instrument English Hardware connection Software connection with WindowsOK to confirm the setting one click Mark local Echo one click 100 101 Switch on the measuring instrument 102OK to confirm Cancel in the next window 103Parity None 104105 106 107 108 109 To quit running the Hyper Terminal To end receiving data from an instrumentSelect END from the pull-down sub-menu one click 110Calibrating the Instrument do Vdc=465.5Flow Rate Measurements Connection of Probes to the Pressure Gauge Data Logger do Probe connection diagram Instrument do113 Turbine probe for measuring flow rate SEL R100 105 110 115 Between 4Classification of Pressure Measurements GaugeConversion Factors and Tables = 3,386 x 103 Pa Psi = PaPsi = kPa = 2,491 x 102 Pa118 Weight / dimensions 320 gr. / 215x73x38 mm Instrument Technical DataConnector DIN 45326 8-pole Minimum, Mean, Relative, A-B differential120 121 Order Codes Guarantee Display blocked Examples of USE of the KeyboardSerial line 124Pressing Data Call repeatedly gives 125Instrument programming Sets hour Sets yearSets day 127Date and time Enables self cut-out +Normal operating Data printing is reduced 128Function Activation or disactivation of the serial outputActivation or disactivation of the Record function Serial output activeActivation and disactivation of the storage function 130Index 131132 Safety EN61000-4-2, EN61010-1 level