Delta DO 9704 manual 120

Page 56

PROBE PRECISION

 

 

 

 

 

GAUGE

ABSOLUTE

 

TEMPE-

 

 

 

 

 

 

DIFFERENTIAL

ABSOLUTE

RELATIVE

ABSOLUTE

 

 

 

 

 

Rated

Maximum

RELATIVE

ABSOLUTE

rear of sensor

rear of sensor

PRECISION

RATURE

WORKING

CONNECTIONS

 

pressure

over-pressure

rear of sensor

rear of sensor

connected to

connected to

20÷25°C

DRIFT

TEMP.

 

connected to

connected to

ambient

vacuum

AT 25°C

 

 

 

 

 

 

 

 

 

 

 

 

GATE 2

vacuum

INSULATED

INSULATED

 

%FS 1°C

 

 

 

 

 

 

 

 

MEMBRANE

MEMBRANE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0 mbar

20.0 mbar

TP705-10MBD

 

 

 

0.50% FSO

0.024

0÷60°C

i= 5 mm TUBE

 

20.0 mbar

40.0 mbar

TP705-20MBD

 

 

 

0.50% FSO

0.024

0÷60°C

i= 5 mm TUBE

 

50.0 mbar

100 mbar

TP705-50MBD

 

 

 

0.50% FSO

0.024

0÷60°C

i= 5 mm TUBE

 

100 mbar

200 mbar

TP705-100MBD

 

 

 

0.25% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

 

 

 

 

 

 

 

 

200 mbar

400 mbar

TP705-200MBD

 

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

TP704-200MBGI

 

0.20% FSO

0.015

0÷80°C

 

1/4 BSP

120

500 mbar

1000 mbar

TP705-500MBD

 

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

TP704-500MBGI

 

0.20% FSO

0.015

0÷80°C

 

1/4 BSP

 

1.00 bar

2.00 bar

TP705-1BD

TP705BARO

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

TP704-1 BGI

 

0.20% FSO

0.015

0÷80°C

 

1/4 BSP

 

2.00 bar

4.00 bar

TP705-2BD

 

 

 

0.12% FSO

0.012

0÷60°C

i= 5 mm TUBE

 

 

 

 

 

TP704-2BGI

TP704-2BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

10.0 bar

20.0 bar

 

 

TP704-10BGI

TP704-10BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

20.0 bar

40.0 bar

 

 

TP704-20BGI

TP704-20BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

50.0 bar

100.0 bar

 

 

TP704-50BGI

TP704-50BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

100 bar

200 bar

 

 

 

TP704-100BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

200 bar

400 bar

 

 

 

TP704-200BAI

0.40% FSO

0.04

0÷80°C

 

1/4 BSP

 

500 bar

750 bar

 

 

 

TP704-500BAI

0.50% FSO

0.04

0÷80°C

 

1/4 BSP

 

1000 bar

1100 bar

 

 

 

TP704-1000BAI

0.50% FSO

0.04

0÷80°C

 

1/4 BSP

N.B.: Differential probes may be used also for relative measurements (use only the socket marked +).

Differential probes may be used also for two-pole measurements (with pressure on the bottom socket marked + and pressure on the socket marked –). The BAROMETRIC probe may be used also for measurements up to 0 bar (vacuum).

ENGLISH

Image 56
Contents Instructions Manual Page Pressure and Temperature DATA-LOGGER English Introduction Keyboard KEY NumbersFunction Description Simbols LIT BesidesNumbers RELSerial Output Simbols LIT Besides Function Numbers DescriptionTom of the display P0+ Press the Prog key to move on to step P1300 Baud 600 BaudP1+ = data dump P1+ StorageHours minutes Seconds This parameter is used for the fol- lowing two functionsFunction P3+ P4+ = set yearP5+ = set month P6+ = set day P7+ = set hours P8+ = set minutes P9+ Self cut-outP10+ To stop storage, press the Enter keyP10 Complete printing Reduced printingP11+ P11Data Call + Start-StopOperating mode When this operativeKEY Simbols LIT Besides Ches itself off againIf the battery symbol does not fla Simbols LIT Besides Function Numbers Description EnterAfter having taken note Restart itMore than 30,000 acquisitions HOW to Measure Probe ConnectionVarious operations Temperature Measurement Method of Using the Instrument and WarningsInstrument Signals and Malfunctions ErrFUL LOULOW Battery Warning and Battery Replacement Storage of the Instrument Serial Interface RS 232CCommand Type Reply Parity None Bit Stop bit Protocol Xon/XoffType of terminal Dumping data from the memoryMemory clear Diagram do PrinterExample of a Report Printed by the Instrument English Hardware connection Software connection with WindowsOK to confirm the setting one click Mark local Echo one click 100 101 Switch on the measuring instrument 102OK to confirm Cancel in the next window 103Parity None 104105 106 107 108 109 To end receiving data from an instrument Select END from the pull-down sub-menu one clickTo quit running the Hyper Terminal 110Calibrating the Instrument do Vdc=465.5Flow Rate Measurements 113 Probe connection diagram Instrument doConnection of Probes to the Pressure Gauge Data Logger do SEL R 100 105 110 115Turbine probe for measuring flow rate Between 4Classification of Pressure Measurements GaugeConversion Factors and Tables Psi = Pa Psi = kPa= 3,386 x 103 Pa = 2,491 x 102 Pa118 Instrument Technical Data Connector DIN 45326 8-poleWeight / dimensions 320 gr. / 215x73x38 mm Minimum, Mean, Relative, A-B differential120 121 Order Codes Guarantee Examples of USE of the Keyboard Serial lineDisplay blocked 124Pressing Data Call repeatedly gives 125Instrument programming Sets year Sets daySets hour 127Enables self cut-out + Normal operatingDate and time Data printing is reduced 128Activation or disactivation of the serial output Activation or disactivation of the Record functionFunction Serial output activeActivation and disactivation of the storage function 130Index 131132 Safety EN61000-4-2, EN61010-1 level