Delta DO 9704 manual P0+, Press the Prog key to move on to step P1, Baud

Page 9

KEY

SIMBOLS LIT BESIDES

 

THE NUMBERS

P0+

+

+

ENGLISH

FUNCTION

DESCRIPTION

There is therefore a limit on the minimum time that may be set as a function of the Baud Rate cho- sen:

BAUD

MINIMUM

SETTABLE

RATE

TIME

 

 

300

Baud

4 sec.

600

Baud

2 sec.

> 600

Baud

1 sec.

- P0 -

When ENTER is pressed with P0 on the display, the instrument returns to normal operating mode without storing any parameter.

Press the PROG key to move on to step P1.

When the skey is pressed with P0 on the channel A display it resets the offset of the connected probe (only for probes for relati- ve or differential measure- ments).

When the tkey is pressed with P0 on the channel B display it resets the offset of the connected probe (only for probes for relati- ve or differential measure- ments).

73

Image 9
Contents Instructions Manual Page Pressure and Temperature DATA-LOGGER English Introduction Numbers Keyboard KEYSimbols LIT Besides Function DescriptionNumbers RELSimbols LIT Besides Function Numbers Description Tom of the displaySerial Output Press the Prog key to move on to step P1 P0+300 Baud 600 BaudP1+ = data dump Storage P1+Hours minutes Seconds This parameter is used for the fol- lowing two functionsFunction P4+ = set year P3+P5+ = set month P6+ = set day P7+ = set hours P8+ = set minutes Self cut-out P9+To stop storage, press the Enter key P10+P10 Complete printing Reduced printingP11 P11+Data Call + Start-StopWhen this operative Operating modeKEY Simbols LIT Besides Ches itself off againSimbols LIT Besides Function Numbers Description Enter If the battery symbol does not flaRestart it More than 30,000 acquisitionsAfter having taken note Probe Connection HOW to MeasureVarious operations Method of Using the Instrument and Warnings Temperature MeasurementErr Instrument Signals and MalfunctionsFUL LOULOW Battery Warning and Battery Replacement Serial Interface RS 232C Storage of the InstrumentParity None Bit Stop bit Protocol Xon/Xoff Command Type ReplyType of terminal Dumping data from the memoryMemory clear Printer Diagram doExample of a Report Printed by the Instrument English Software connection with Windows Hardware connectionOK to confirm the setting one click Mark local Echo one click 100 101 102 Switch on the measuring instrument103 OK to confirm Cancel in the next window104 Parity None105 106 107 108 109 Select END from the pull-down sub-menu one click To end receiving data from an instrumentTo quit running the Hyper Terminal 110Vdc=465.5 Calibrating the Instrument doFlow Rate Measurements Probe connection diagram Instrument do Connection of Probes to the Pressure Gauge Data Logger do113 100 105 110 115 SEL RTurbine probe for measuring flow rate Between 4Gauge Classification of Pressure MeasurementsConversion Factors and Tables Psi = kPa Psi = Pa= 3,386 x 103 Pa = 2,491 x 102 Pa118 Connector DIN 45326 8-pole Instrument Technical DataWeight / dimensions 320 gr. / 215x73x38 mm Minimum, Mean, Relative, A-B differential120 121 Order Codes Guarantee Serial line Examples of USE of the KeyboardDisplay blocked 124125 Pressing Data Call repeatedly givesInstrument programming Sets day Sets yearSets hour 127Normal operating Enables self cut-out +Date and time Data printing is reduced 128Activation or disactivation of the Record function Activation or disactivation of the serial outputFunction Serial output active130 Activation and disactivation of the storage function131 Index132 EN61000-4-2, EN61010-1 level Safety