21
Views on the Edge
Definitions of data log values and views
|
|
|
|
|
|
|
|
| Views on the |
|
| Explanation |
| ||
| Edge |
|
|
|
| ||
|
|
|
|
|
| Memory storage symbol – |
|
|
|
|
|
|
| eg4: The eg4 model displays the total memory storage |
|
|
|
|
|
|
| remaining in hours and minutes. For example, if it displays the |
|
|
|
|
|
|
| memory symbol 181:50 this represents 181 hours and 50 |
|
|
|
|
|
|
| minutes of memory storage remaining on the dosimeter. |
|
|
|
|
|
|
| eg3: The eg3 model displays the memory by indicating the |
|
|
|
|
|
|
| remaining number of studies it will store into memory. For |
|
|
|
|
|
|
| example, if the eg3 displays “50” this indicates you can store 50 |
|
|
|
|
|
|
| studies on the dosimeter. (Note: the difference is because the |
|
|
|
|
|
|
| eg3 model does not data log. This is an older model.) |
|
|
|
|
|
|
| Calendar symbol– The calendar symbol and calendar field |
|
|
|
|
|
|
| displays the |
|
|
|
|
|
|
| Battery power clock symbol – The battery power clock |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| symbol identifies the number of hours and minutes of battery |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| time remaining on the dosimeter. |
|
|
|
|
|
|
|
|
|
|
|
|
| Table |
|
Edge Measurement descriptors/variants
The following is an explanation of the Edge descriptors and equivalents for Lmax, Lmin, & Lpk.
|
|
|
|
| Descriptors | Variants |
|
|
|
| |
| Lmax variants | Sound pressure level - is the basic measure of noise loudness, expressed | |
|
| in decibels. (In DMS this is noted as “SPL”) |
|
| LASMX | Maximum sound level- is the highest sound level recorded during a | |
|
| measurement interval with a particular response setting (Slow or Fast) and | |
|
| weighting (A or C). LMax is the highest value that is included in LAvg or | |
|
| dose calculations. |
|
|
| Under OSHA regulations, unprotected workers may not be exposed to | |
|
| maximum sound levels greater than 115 dB, measured with a Slow | |
|
| response rate. |
|
| LCPK | Peak Level - is the highest instantaneous sound pressure level recorded | |
|
| during a measurement interval. Unlike the maximum level, the peak is | |
|
| detected independently of dosimeter settings for response rate or weighting. | |
|
| Under OSHA regulations, unprotected workers may not be exposed to peak | |
|
| sound levels greater than 140 dB. |
|
| LASMN | Minimum sound level - The lowest sampled sound level during the | |
|
| measurement interval allowing for the unit’s Response Time setting (Fast or | |
|
| Slow). |
|
|
|
|
|
| Table |
| |
Page 21 | eg4 |