3M 44, 46 user manual Parallel, Heat Stress Report

Page 25

20

Parallel

Parallel

Data can be sent directly to parallel printers that accept direct ASCII test input without special drivers. Make sure the printer is powered on and is online, ready to accept data, prior to printing.

 

QUEST TECHNOLOGIES, a 3M company

Page 1

 

HEAT STRESS REPORT

 

File Name

_________________________ QUESTempº46 Rev 1.00

 

Serial # TK09090909

Employee

_________________________

 

Facility

_________________________ Session (3)

 

 

Start: 21-NOV-09

11:07:32

Department ________________________ Stop: 21-NOV-09 11:10:15

Job _________________________ Printed: 21-NOV-09 11:16:00

Comments/Notes______________________________________________

____________________________________________________________

Logging Interval: 1 minutes Degrees Fahrenheit

MAXIMUM LEVELS, Sensor 1

WBGT

68.3

21-NOV-09 11:10:08

DRY BULB

82.7

21-NOV-09 11:09:56

GLOBE

91.4

21-NOV-09 11:10:12

REL HUMIDITY

14%

21-FEB-08 11:07:32

FLOW (m/s)

0.6

21-FEB-08 11:09:08

MAXIMUM LEVELS, Sensor 2

WBGT

80.5

21-FEB-08 11:10:11

DRY BULB

99.2

21-FEB-08 11:09:07

GLOBE

106.1

21-FEB-08 11:10:06

HEAT INDEX

0

00-XXX-00 00:00:00

REL HUMIDITY

15%

21-FEB-08 11:07:32

MAXIMUM LEVELS, Sensor 3

WBGT

68.6

21-FEB-08 11:09:56

DRY BULB

88.6

21-FEB-08 11:10:08

GLOBE

93.0

21-FEB-08 11:10:03

HEAT INDEX

0

00-XXX-00 00:00:00

REL HUMIDITY

11%

21-FEB-08 11:07:32

MAXIMUM LEVELS, Sensor(WEIGHTED AVERAGE)

WBGT

71.4

21-FEB-08 11:10:14

SESSION: 1

Page 2

Sensor: 1

 

Degrees Fahrenheit

Stay Times: ACGIH, Acclimated, WBGT, clo correction = 1.0 °C

TIME WBGT

DRY GLOBE RH HI FLOW L

M

H

VH

11:08

67.9

82.4

90.7

13

0

0.5

60

60

60

60

11:09

68.1

82.6

91.3

12

0

0.5

60

60

60

60

SESSION: 1

 

 

 

 

 

Page 3

 

Sensor: 2

 

 

 

 

 

 

 

 

 

Degrees Fahrenheit

Stay Times: ACGIH, Acclimated, WBGT, clo correction = 1.0 °C

TIME WBGT

DRY GLOBE RH HI L

M

H

VH

11:08

79.3

98.9

104.5

15

0

60

45

30

15

11:09

80.2

99.2

105.6

15

0

60

45

30

15

SESSION: 1

 

 

 

 

 

 

Page 4

Sensor: 3

 

 

 

 

 

 

 

 

Degrees Fahrenheit

 

 

 

 

 

 

 

Stay Times: ACGIH, Acclimated, WBGTi, clo correction = 1.0 °C

TIME WBGT DRY GLOBE RH HI L

M

H

VH

11:08

68.1

88.0

92.7

11

0

60

60

60

60

11:09

68.4

88.3

92.9

11

0

60

60

60

60

SESSION: 2

 

 

 

 

 

 

Page 5

Sensor: WBGT(W-AVG) = .50*WBGT(1) + .25*WBGT(2) + .25*WBGT(3) Degrees Fahrenheit

Stay Times: ACGIH, Acclimated, WBGT, clo correction = 1.0 C WBGT WBGTo

TIME

W-AVG

W-AVG

L

M

H

VH

-----

-----

-----

---

---

---

---

11:08

71.5

70.8

60

60

60

60

11:09

71.8

71.1

60

60

60

45

Figure 1-26: Report using parallel printer

Image 25
Contents Market Leader Contents Displayed Items Iii List of Tables List of FiguresQUESTempº Models IntroductionUp and Running overview Getting StartedKeypad Operation Up Arrow key Enter keyDown Arrow key Run Stop keyPlacing the QUESTempº 44/46 on the job site Turning on/off and basic operationAbout the sensor bar SensorsGlobe Thermometer Waterless Wetbulb Sensor and Relative Humidity SensorRemote, Sensors 2 Tri-sensor weighted averageComputing Waterless wetbulb and wind speed Waterless WetbulbStay Times/Rest Times QTº46 only WetBulb Globe TemperatureHeat Index/Humidex AirflowThermal Comfort Operating QUESTempº 44/46 SetupView Index Setting Notes Setup for Waterless Wetbulb measurement airflow ratePrint ResetRun Flow 0.3m/s  Displayed ItemsStay Time DateData Logging Data LoggingPerforming an electronic sensor check Electronic sensor checkRH Sensor Alignment Sensor AlignmentLow RH Alignment screen Adjust % to 33% using up/down arrow PrintingPrinting PrintingSerial Heat Stress Report ParallelAirflow Functionality Airflow functionalityOperating sequence Operational CheckData Logging Airflow Batteries for Air ProbeVolt Alkaline Battery Replacement Power optionsApproved 9-Volt Batteries 29 NiMH rechargeable battery NiMH Battery PackAppendix a Appendix a SpecificationsCharge Time NiMH Battery Pack Appendix B Appendix B Heat Exposure TablesUnited States Navy Acgih Clothing CorrectionsUnited States Navy Flag Conditions for U.S. Navy/Marine Corp. Ashore Electrical power research institute EpriAir Probe Accessories Appendix C AccessoriesAppendix C Appendix D 3MTM Detection Management Software DMS Communication setupQUESTempo 44/46 Appendix D31 QT⁰44/46 downloading data 32 Downloading QT⁰44/46 files Downloading data with the QT⁰44/46Viewing Data in DMS Charts and Graphs in Panel layout view PLVSelecting a session/study 34 QT⁰44/46 data in panel layout view Remember setting Reports and Printing Inserting on-site testing imagesWarranty 3M ServiceService Department and Technical Support 1 800 CalibrationAbout Us About 3M Personal Safety