29

Appendix B

United States Navy

WBGT(F)

I

II

III

IV

V

VI

92.0

4:50

4:10

3:30

2:55

2:15

1:30

93.0

4:25

3:50

3:15

2:40

2:00

1:25

94.0

4:05

3:35

3:00

2:25

1:50

1:15

95.0

3:45

3:15

2:45

2:15

1:45

1:10

96.0

3:25

3:00

2:30

2:05

1:35

1:05

97.0

3:10

2:45

2:20

1:55

1:25

1:00

98.0

2:55

2:35

2:10

1:45

1:20

0:55

99.0

2:40

2:20

2:00

1:40

1:15

0:50

100.0

2:30

2:10

1:50

1:30

1:10

0:45

101.0

2:20

2:00

1:40

1:25

1:05

0:45

102.0

2:10

1:50

1:35

1:15

1:00

0:40

103.0

2:00

1:45

1:25

1:10

0:55

0:35

104.0

1:50

1:35

1:20

1:05

0:50

0:35

105.0

1:40

1:30

1:15

1:00

0:45

0:30

106.0

1:35

1:25

1:10

0:55

0:45

0:30

107.0

1:30

1:15

1:05

0:50

0:40

0:25

108.0

1:20

1:10

1:00

0:50

0:35

0:25

109.0

1:15

1:05

0:55

0:45

0:35

0:25

110.0

1:10

1:00

0:50

0:40

0:30

0:20

111.0

1:05

1:00

0:50

0:40

0:30

0:20

112.0

1:00

0:55

0:45

0:35

0:25

0:20

113.0

0:55

0:50

0:40

0:35

0:25

0:15

114.0

0:55

0:45

0:40

0:30

0:25

0:15

115.0

0:50

0:45

0:35

0:30

0:20

0:15

116.0

0:45

0:40

0:35

0:25

0:20

0:15

117.0

0:45

0:40

0:30

0:25

0:20

0:10

118.0

0:40

0:35

0:30

0:25

0:15

0:10

119.0

0:35

0:35

0:25

0:20

0:15

0:10

120.0

0:35

0:30

0:25

0:20

0:15

0:10

121.0

0:35

0:30

0:25

0:20

0:15

0:10

122.0

0:30

0:25

0:20

0:15

0:15

0:10

123.0

0:30

0:25

0:20

0:15

0:10

0:10

124.0

0:25

0:25

0:20

0:15

0:10

0:05

Image 34 Contents
Market Leader Contents Displayed Items Iii List of Figures List of TablesIntroduction QUESTempº ModelsUp and Running overview Getting StartedKeypad Operation Down Arrow key Enter keyUp Arrow key Run Stop keyTurning on/off and basic operation Placing the QUESTempº 44/46 on the job siteGlobe Thermometer SensorsAbout the sensor bar Waterless Wetbulb Sensor and Relative Humidity SensorTri-sensor weighted average Remote, Sensors 2Waterless Wetbulb Computing Waterless wetbulb and wind speedHeat Index/Humidex WetBulb Globe TemperatureStay Times/Rest Times QTº46 only AirflowThermal Comfort Operating QUESTempº 44/46 SetupView Setup for Waterless Wetbulb measurement airflow rate Index Setting NotesPrint ResetRun Displayed Items Flow 0.3m/s Date Stay TimeData Logging Data LoggingElectronic sensor check Performing an electronic sensor checkSensor Alignment RH Sensor AlignmentLow RH Alignment screen Adjust % to 33% using up/down arrow PrintingPrinting PrintingSerial Parallel Heat Stress ReportAirflow functionality Airflow FunctionalityData Logging Airflow Operational CheckOperating sequence Batteries for Air ProbeVolt Alkaline Battery Replacement Power optionsApproved 9-Volt Batteries NiMH Battery Pack 29 NiMH rechargeable batteryAppendix a Specifications Appendix a Charge Time NiMH Battery Pack Appendix B Heat Exposure Tables Appendix BAcgih Clothing Corrections United States NavyUnited States Navy Electrical power research institute Epri Flag Conditions for U.S. Navy/Marine Corp. AshoreAir Probe Accessories Appendix C AccessoriesAppendix C QUESTempo 44/46 Communication setupAppendix D 3MTM Detection Management Software DMS Appendix D31 QT⁰44/46 downloading data Downloading data with the QT⁰44/46 32 Downloading QT⁰44/46 filesViewing Data in DMS Charts and Graphs in Panel layout view PLVSelecting a session/study 34 QT⁰44/46 data in panel layout view Remember setting Inserting on-site testing images Reports and PrintingService Department and Technical Support 1 800 3M ServiceWarranty CalibrationAbout 3M Personal Safety About Us