Toshiba TOSVERT VF-AS1 instruction manual Bytes Blank Start Code

Page 16

efesotomasyon.com -Toshiba inverter,drive,servo,plc

E6581315

„Inverter → Computer

At time of broadcast communication of the binary mode, returning of data is not executed except for the inverter to be returned (inverter number 00H) and when the inverter number is not matched. This is because there will be a risk that the returned data may be deformed.

1) Normal processing

Omissible

 

Number of read data groups x 2 bytes

 

 

 

 

(3.5 bytes Blank)

Start Code

“/”

INV CMD No. “Y”

Number

Write

Read

Read

Read

Read

Read

Read

Read

Read

Read

Read

SUM

of Read

Status

data1

data1

data2

data2

data3

data3

data4

data4

data5

data5

 

Data

 

high

low

high

low

high

low

high

low

high

low

 

Groups

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3.5

bytes

Blank)

Checksum area

1.2FH “/” (1 byte) Start code in binary mode

2.INV-NO (1Byte) Inverter number・・・00H to 3FH

If the inverter number matches up with that specified from the operation panel, data will be returned from the inverter. If the inverter number does not match, the data will be judged invalid and no data will be returned.

Communication data will be invalidated and data will not be returned either if the in- verter number does not match. (Inverter number is considered matched if it is omitted during reception)

3. CMD(1Byte)

:‘Y’ (Block communication command [monitoring])

 

Lowercase letter ‘y’ during an inverter trip, including standing by for retrying and during

atrip.

4.Number of read data groups (1 byte)

:Return the number of data groups to be read (00H to 05H).

5. Write status (1 byte) : Return 00H to 03H.

*Failing to write in the specified parameter in the number of write data groups, set “1” in the corresponding bit for the parameter failed to write. (See below.)

Bit Position

7

6

5

 

4

3

2

1

0

Data Type

 





6.Read data1 - 5 (2 bytes)

:Return according to the number of read data groups. “0000H” is returned as dummy

data if “0” is selected as a parameter.

Read data1: Data selected by . Read data2: Data selected by .

Read data3: Data selected by . Read data4: Data selected by .

Read data5: Data selected by .

7.SUM(1Byte) : Checksum (Cannot be omitted) 00H to FFH

Lower two digits (1 byte) of total sum from start code of return data to read data.

„Example

(When set as follows:  =  (Command information 1),  =  (frequency command),

 =  (status information), =  (output frequency),  =  (output current),  =  (output voltage) and  =  (alarm information)

Computer → Inverter2F 58 02 05 C4 00 17 70 D9

Inverter → Computer2F 59 05 03 00 00 00 00 00 00 00 00 00 00 90 (When parameter is not set)

Inverter → Computer2F 59 05 00 40 00 00 00 00 00 00 00 00 00 CD CD (When parameter is set)

Inverter → Computer2F 59 05 00 64 00 17 70 1A 8A 24 FD 00 00 3D (During operation at 60Hz)

15

Image 16
Contents Tosvert VF-AS1 Series RS485 Communication Function E6581315②Read first Safety precautions E6581315Contents BIT15 BIT8BIT7 BIT0 General outlines of the communication functionBit Word Data transmission specifications BIT2About the handling of received frames Communication protocolMOUBUS-RTU Binary mode 2FH Toshiba Inverter ProtocolData transmission format used in Ascii mode Data transmission formatINV-NO CMD Data5bytes Blank 28H Bytes Checksum areaINV-NO Data SUMData transmission format used in binary mode Command received Returned for the 57H W and 50H P commandsByte Bytes Sum 1 bytes Checksum not omissible 00H to FFH Norn 2FH Byte 4EH6EH BytesTransmission format of Block Communication Page Bytes Blank Start Code INV-NO Commands Dummy data is required for this commandReads the data with the specified communication number Block communication Computer InverterRFE03CR RFE03077BCRPage Format error Data transmission format does not match Transmission errorsCommunication There is no communication number that matches Broadcast communication function VF-AS1 Examples of the use of communication commands Ascii mode Computer → Inverter Inverter → ComputerFrom the computer H = 24d  trip status RFC90CRExamples of Communication programs =LENS$ For I=1 to L NextInput #1,B$ GotoIf Count 0 then T=TIMER 160 T=TIMER COUNT=TIMER-TPrint #1,B$ Page MSComm1.Output = Text2.Text & Chr13 End Sub End IfText2.Text = Text1.Text = End Sub MODBUS-RTU protocol Inverter number MODBUS-RTU transmission format Read commandCRC Write command Blank Command 1 byte5bytes Blank Command 1 byte Text size is 8 bytes fixed InverterError codes CRC GenerationBit counter = End Return CRCInter-drive communication E6581315 QWiring 2-wire RS485 communication Never use pin-7 P11 QWiring 4-wire RS485 communication)Page Parameters relating to the slave side example Proportional control of speed =0.01%Slave 100.00Hz 00% 90.00Hz 45.00HzSlave 100.00Hz1 00% 80.00Hz 40.00HzTransmission format for inter-drive communication INV-NO 1 byte Inverter numberCommunication parameters 0OFFMODBUS-RTU Baud rate,  , Parity  Inverter number„ Timer Time-out period Computer link PC → INVMaster INV To Slave INV INV → PC PC → INVFree notes Send waiting time , Use this function for the following case Commands and monitoring from the computer Communication commands commands from the computerPI OFF OFFElectric Power quantity Forcibly braked Preliminary excitationBrake release B Braking answer BAWire RS485 communication FA32 „ Terminal board output data FA50 „ FM analog output FA51„ AM analog output FA52 Output terminal no Specified data outputRFD00CR Monitoring from the computerUnit 0.01% N·m „ Input terminal board status FD06, FE06 RESInput terminal function selection 9 f119 BIT15„ Output terminal board status FD07, FE07 „ Inverter operating status 1 FD01, FE01 ST=ON ST=OFF„ Inverter operating status 2 FD42, FE42 „ Inverter operating status 3 FD49, FE49„ Inverter operating frequency mode status FD46, FE46 „ Inverter operating command mode status FD45, FE45Preset speed operation „ Cumulative operation time alarm monitor FE79 „ Alarm information monitor FC91Bit Specifications Remarks E6581315 „ Inverter model capacity code FB05 Model DataParameter Name Range Setting LED setting by communicationUtilizing panel LEDs and keys by communication „ Block Communication Function for LED Display Ascii LED display data code 00H-1FH are blank BlankFA10=0 Key utilization by communicationFA10=1 Parameter data EEP ROMPage Alarm code FE02 Frequency command value 01HzFE19 Torque command FE29 Input powerE6581315 FD50 Light-load high-speed torque 01% Tion FE80 Cumulative power on timeFE84 Binary input value option Appendix 1 Table of data codes CanSUB ESCAppendix 2 Response time Response time „ Data transmission timeAppendix 3 Compatibility with the communication function VF-A7Appendix 4 Troubleshooting Appendix 5 Connecting for RS485 communication RXA RXBTXA TXB
Related manuals