LSI AP1172-E1 manual Weights

Page 15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Area Requirements

Weights

The total weight depends on the type and quantity of modules installed in the cabinet. Table 1-1lists the overall weight of the cabinet, plus the maximum weight for each module. Use these weights to estimate the total weight of your system, based on the number of modules installed in the cabinet.

Table 1-1 Cabinet, Crate, and Module Weights

Cabinets and Modules

 

Unit Weight

 

 

 

Cabinet

Empty

123.0 kg (270.0 lb)

 

 

 

Pallet and Packaging1

Empty

98.0 kg (215.0 lb)

E2400 10x Array Module

Maximum

50.8 kg (112 lb)

Deskside, Low Profile (LP) drives2

 

 

E2400 10x Array Module

Maximum

54.4 kg (120.0 lb)

Deskside, Half Height (HH) drives3

 

 

E2400 10x Array Module

Maximum

38.9 kg (86.4 lb)

Rackmount, LP drives

 

 

 

 

 

E2400 10x Array Module

Maximum

42.3 kg (94.0 lb)

Rackmount, HH drives

 

 

 

 

 

E2400 14x Array Module

Maximum

52.84 kg (116.5 lb)

Deskside, LP drives

 

 

 

 

 

E2400 14x Array Module

Maximum

40.95 kg (90.5 lb)

Rackmount, LP drives

 

 

 

 

 

FC-1 10x Drive Module

Maximum

44.5 kg (98.0 lb)

Deskside, LP drives

 

 

 

 

 

FC-1 10x Drive Module

Maximum

47.8 kg (105.0 lb)

Deskside, HH drives

 

 

 

 

 

FC-1 10x Drive Module

Maximum

38.3 kg (84.4 lb)

Rackmount, LP drives

 

 

 

 

 

FC-1 10x Drive Module

Maximum

41.7 kg (92.0 lb)

Deskside, HH drives

 

 

 

 

 

FC-1 14x Drive Module

Maximum

40.95 kg (90.5 lb)

Rackmount, LP drives

 

 

 

 

 

FC-2 14x Drive Module

Maximum

30.87 kg (68 lb)

Rackmount, LP drives

 

 

 

 

 

E4400 Command Module

Maximum

55.6 kg (122.3 lb)

 

 

 

E4600 or E5600 Command Module

Maximum

43.99 kg (97.0 lb)

 

 

 

1Add for international shipments only

2Low-Profile drives

3Half-Height drives

Command Module and Drive Module Site Preparation Guide

1-5

Image 15
Contents Command Module and Drive Module Copyright Notice Regulatory Compliance Statements First Edition September New Book Contents Array Module Site Preparation Drive Module Site PreparationList of Figures Command Module and Drive Module Site Preparation Guide List of Tables E2400 Inch Cabinet Site Preparation Cabinet Features Cabinet Features Area Requirements Weights Cabinet Dimensions DimensionsRange TemperatureConfiguration C1 AltitudeCircuit Breaker Domestic International AC PowerAC Plug ReceptacleCabinet AC Distribution AC Power Distribution BoxesCabinet Ladder Cord Ladder CordsTypes of 72-Inch Cabinet Power Cords and Receptacles Power Cords and ReceptaclesSite Wiring Command Module Site Preparation Module Rackmount CommandBattery Power SupplyCommand Module RackmountModule SFP Minihub Command Module Dimensions Shipping Carton DimensionsAirflow Command Module AirflowOperating, Storage 30.5 m 100 ft Below Sea Level Transit SoundModel Heat Dissipation Power Cord Routing Redundant Command Module AC Power Connections Types of 72-Inch Cabinet AC Power Cords and Receptacles Site Wiring Interface Cables and Connections E4400 Command ModuleCopper fiber Fiber opticSFP Transceiver and Fiber Optic Cable E4600 and E5600 Command ModulesMaximum Part Length Page Drive Module Site Preparation Fan Drive Module01 kg 2.23 lb 92 kg 4.23 lb LP Drive, 73 GBDimensions FC-1 14x and FC-2 14x Drive Module Dimensions Deskside Sound Power Bels Sound Pressure Unit of Measure FC-2 14x Drive Module Power Requirements Redundant AC Power Connections to Drive Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring FC-1 10x and FC-1 14x Drive Modules Part Length Speed Range Number FC-2 14x Drive Module Page Array Module Site Preparation Array Module Unit Maximum Unit1 Empty Unit2 Shipping3 Dimensions E2400 E2400 14x Array Module DimensionsArray Module Airflow Sound Power Bels Sound Pressure 60 dBA Idle Current 39 a Redundant AC Power Connections to Array Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring Optical Copper Speed Range Number Page Index