LSI AP1172-E1 manual Sound Power Bels Sound Pressure

Page 45

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements

Environmental Requirements

The drive module is designed to operate in the environment defined in Table 3-5and Table 3-6 on page 3-7.

Table 3-5 Drive Module Environmental Requirements

Condition

Parameter

Requirement

 

FC-1 10x, FC-1 14x, and FC-2 14x

 

 

 

 

 

 

 

 

 

Operating Range

10° C to 40° C (50° F to 104° F)

 

 

Maximum Rate of Change

10° C (18° F) per hour

Temperature

 

Storage Range

-10°C to 50° C (14° F to 122° F)

 

Maximum Rate of Change

15° C (27° F) per hour

 

 

 

 

Transit Range

-40°C to 60° C (-40°F to 140° F)

 

 

Maximum Rate of Change

20° C (36° F) per hour

 

 

Operating Range

20% to 80%

 

 

 

 

 

 

Storage Range

10% to 90%

Relative Humidity

 

 

 

 

Transit Range

5% to 95%

No condensation

 

 

 

 

 

 

Maximum Dew Point

26° C (79° F)

 

 

Maximum Gradient

10% per hour

 

 

 

 

Sound

 

Sound Power

6.0 bels

 

 

 

 

Sound Pressure

60 dBA

 

 

 

 

 

Altitude

Operating and Storage

3000 m (9840 ft.)

(Above Sea Level)1

 

 

 

 

Transit

12,000 m (40,000 ft.)

 

 

 

Altitude

Operating, Storage, and Transit

30.5 m (100 ft.)

(Below Sea Level)

 

 

 

 

 

 

1 If you plan to operate a drive module at altitudes between 1000 m to 3000 m (3280 ft. to 9850 ft.) above sea level, lower the environmental temperature 1.7° C (3.3° F) for every 1000 m (3280 ft.) above sea level.

Table 3-6 Drive Module Heat Dissipation

Model

Low Profile (LP)

Half Height (HH)

18 GB and 36 GB Drives

36 GB and 73 GB Drives

 

 

 

 

FC-1 10x

1036 Btu/hr (0.306 kVA or 303 W)

1070 Btu/hr (0.33 kVA or 313 W)

 

 

 

FC-1 14x

1050 Btu/hr (0.309 kVA or 306 W)

Not applicable.

 

 

 

FC-2 14x

1084 Btu/hr (0.320 kVA or 317 W)

Not applicable.

 

 

 

Command Module and Drive Module Site Preparation Guide

3-7

Image 45
Contents Command Module and Drive Module Copyright Notice Regulatory Compliance Statements First Edition September New Book Contents Array Module Site Preparation Drive Module Site PreparationList of Figures Command Module and Drive Module Site Preparation Guide List of Tables E2400 Inch Cabinet Site Preparation Cabinet Features Cabinet Features Area Requirements Weights Cabinet Dimensions DimensionsConfiguration C1 TemperatureAltitude RangeAC Plug Domestic International AC PowerReceptacle Circuit BreakerCabinet AC Distribution AC Power Distribution BoxesCabinet Ladder Cord Ladder CordsTypes of 72-Inch Cabinet Power Cords and Receptacles Power Cords and ReceptaclesSite Wiring Command Module Site Preparation Battery Rackmount CommandPower Supply ModuleCommand Module RackmountModule SFP Minihub Command Module Dimensions Shipping Carton DimensionsAirflow Command Module AirflowOperating, Storage 30.5 m 100 ft Below Sea Level Transit SoundModel Heat Dissipation Power Cord Routing Redundant Command Module AC Power Connections Types of 72-Inch Cabinet AC Power Cords and Receptacles Site Wiring Interface Cables and Connections E4400 Command ModuleCopper fiber Fiber opticSFP Transceiver and Fiber Optic Cable E4600 and E5600 Command ModulesMaximum Part Length Page Drive Module Site Preparation Fan Drive Module01 kg 2.23 lb 92 kg 4.23 lb LP Drive, 73 GBDimensions FC-1 14x and FC-2 14x Drive Module Dimensions Deskside Sound Power Bels Sound Pressure Unit of Measure FC-2 14x Drive Module Power Requirements Redundant AC Power Connections to Drive Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring FC-1 10x and FC-1 14x Drive Modules Part Length Speed Range Number FC-2 14x Drive Module Page Array Module Site Preparation Array Module Unit Maximum Unit1 Empty Unit2 Shipping3 Dimensions E2400 E2400 14x Array Module DimensionsArray Module Airflow Sound Power Bels Sound Pressure 60 dBA Idle Current 39 a Redundant AC Power Connections to Array Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring Optical Copper Speed Range Number Page Index