LSI AP1172-E1 manual FC-2 14x Drive Module Power Requirements

Page 47

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements

Table 3-9 FC-2 14x Drive Module Power Requirements

Item

Unit of Measure

Requirement

 

 

 

Circuit Breaker

Slow-blow Fuse

10 A per Power Supply

 

 

 

 

 

 

Low Range

High Range

 

 

 

 

 

Nominal Voltage

90 to 136 VAC

198 to 264 VAC

 

 

 

 

 

Frequency

50 to 60 Hz

50 to 60 Hz

AC Power

 

 

 

Idle Current

2.93 A1

1.27 A2

 

 

Maximum Operating Current

3.18 A1

1.37 A2

 

Maximum Surge Current

5.85 A1

2.36 A2

1Typical current: 100 V AC, 60 Hz at 0.73 power efficiency, 0.99 power factor.

2Typical current: 240 V AC, 60 Hz at 0.73 power efficiency, 0.99 power factor.

Power Cord Routing

All modules are shipped with two AC power cords that are appropriate for use in a typical outlet in the destination country. Each power cord connects one of the power supplies in a module to an independent, external power source, such as a wall receptacle or uninterruptible power supply (UPS). If you have a rackmount cabinet with internal power cabling, such as a ladder cable, you do not need these power cords.

Typically, a rackmount cabinet has two AC power distribution boxes with separate power cords (Figure 3-4). To ensure redundancy, each power cord must connect to an independent, external power source. Each AC power distribution box has a ladder cable that runs up the inside of the cabinet and connects to one of the power supplies in each module.

Figure 3-5 on page 3-11shows the power cords and receptacles for domestic and international use.

Command Module and Drive Module Site Preparation Guide

3-9

Image 47
Contents Command Module and Drive Module Copyright Notice Regulatory Compliance Statements First Edition September New Book Contents Array Module Site Preparation Drive Module Site PreparationList of Figures Command Module and Drive Module Site Preparation Guide List of Tables E2400 Inch Cabinet Site Preparation Cabinet Features Cabinet Features Area Requirements Weights Cabinet Dimensions DimensionsRange TemperatureConfiguration C1 AltitudeCircuit Breaker Domestic International AC PowerAC Plug ReceptacleCabinet AC Distribution AC Power Distribution BoxesCabinet Ladder Cord Ladder CordsTypes of 72-Inch Cabinet Power Cords and Receptacles Power Cords and ReceptaclesSite Wiring Command Module Site Preparation Module Rackmount CommandBattery Power SupplyModule SFP Minihub Command ModuleRackmount Command Module Dimensions Shipping Carton DimensionsAirflow Command Module AirflowOperating, Storage 30.5 m 100 ft Below Sea Level Transit SoundModel Heat Dissipation Power Cord Routing Redundant Command Module AC Power Connections Types of 72-Inch Cabinet AC Power Cords and Receptacles Site Wiring Interface Cables and Connections E4400 Command ModuleCopper fiber Fiber opticSFP Transceiver and Fiber Optic Cable E4600 and E5600 Command ModulesMaximum Part Length Page Drive Module Site Preparation Fan Drive Module01 kg 2.23 lb 92 kg 4.23 lb LP Drive, 73 GBDimensions FC-1 14x and FC-2 14x Drive Module Dimensions Deskside Sound Power Bels Sound Pressure Unit of Measure FC-2 14x Drive Module Power Requirements Redundant AC Power Connections to Drive Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring FC-1 10x and FC-1 14x Drive Modules Part Length Speed Range Number FC-2 14x Drive Module Page Array Module Site Preparation Array Module Unit Maximum Unit1 Empty Unit2 Shipping3 Dimensions E2400 E2400 14x Array Module DimensionsArray Module Airflow Sound Power Bels Sound Pressure 60 dBA Idle Current 39 a Redundant AC Power Connections to Array Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring Optical Copper Speed Range Number Page Index