Table 2-6

Command Module Heat Dissipation

 

 

Model

 

Heat Dissipation

 

 

 

E4400

 

657.5 Btu/hr (0.1925 kVA or 192.5 W)

 

 

 

E4600

 

790.0 Btu/hr (0.2333 kVA or 231.0 W)

 

 

 

E5600

 

786.6 Btu/hr (0.2300 kVA or 230.0 W)

 

 

 

Command Module and Drive Module Site Preparation Guide

2-7

Image 29
Contents Command Module and Drive Module Copyright Notice Regulatory Compliance Statements First Edition September New Book Contents Array Module Site Preparation Drive Module Site PreparationList of Figures Command Module and Drive Module Site Preparation Guide List of Tables E2400 Inch Cabinet Site Preparation Cabinet Features Cabinet Features Area Requirements Weights Cabinet Dimensions DimensionsConfiguration C1 TemperatureAltitude RangeAC Plug Domestic International AC PowerReceptacle Circuit BreakerCabinet AC Distribution AC Power Distribution BoxesCabinet Ladder Cord Ladder CordsTypes of 72-Inch Cabinet Power Cords and Receptacles Power Cords and ReceptaclesSite Wiring Command Module Site Preparation Battery Rackmount CommandPower Supply ModuleModule SFP Minihub Command ModuleRackmount Command Module Dimensions Shipping Carton DimensionsAirflow Command Module AirflowOperating, Storage 30.5 m 100 ft Below Sea Level Transit SoundModel Heat Dissipation Power Cord Routing Redundant Command Module AC Power Connections Types of 72-Inch Cabinet AC Power Cords and Receptacles Site Wiring Interface Cables and Connections E4400 Command ModuleCopper fiber Fiber opticSFP Transceiver and Fiber Optic Cable E4600 and E5600 Command ModulesMaximum Part Length Page Drive Module Site Preparation Fan Drive Module01 kg 2.23 lb 92 kg 4.23 lb LP Drive, 73 GBDimensions FC-1 14x and FC-2 14x Drive Module Dimensions Deskside Sound Power Bels Sound Pressure Unit of Measure FC-2 14x Drive Module Power Requirements Redundant AC Power Connections to Drive Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring FC-1 10x and FC-1 14x Drive Modules Part Length Speed Range Number FC-2 14x Drive Module Page Array Module Site Preparation Array Module Unit Maximum Unit1 Empty Unit2 Shipping3 Dimensions E2400 E2400 14x Array Module DimensionsArray Module Airflow Sound Power Bels Sound Pressure 60 dBA Idle Current 39 a Redundant AC Power Connections to Array Modules 250 VAC, 16 A, IEC 320-C19 Cord Site Wiring Optical Copper Speed Range Number Page Index