1. INSTALLATION
1.7Connection of External Equipment
1.7.1General wiring
All external equipment are terminated on the MAIN Board inside the processor unit. Turn off the power and unfasten four screws to remove the cover. Connect wiring from external equipment referring to the interconnection diagram. Use the terminal opener supplied to open terminal blocks, referring to the instructions below.
Recommended Cables*:
Power cable:
IEC 61162 equipment:
How to insert cores in terminal blocks
Opener
1. Insert opener.
2. Press opener.
3. Insert core.
4. Release opener.
Power Cable
From top: Analog Roll, Analog Pitch,
LOG/ALARM (Contact signal,
DATA IN
BEACON EXT (RTCM
DATA OUT6
DATA
Processor unit, cover opened
Note 1: Attach labels (supplied) to cables to differentiate between them.
Note 2: A plastic sheet is placed across the cable glands of the processor unit to keep out foreign material. Cut out holes in the plastic where cables are to be lead in.
Note 3: Roll, pitch analog out voltage [V] = 0.0785 x θ (deg.) + 3.5 (θ = roll, pitch angle) Output example
Roll or pitch angle | Analog out voltage |
0 [deg] | 3.5 [V] |
5 [deg] | 3.8925 [V] |
10 [deg] | 4.285 [V] |
20 [deg] | 5.07 [V] |