Furuno FR-2125V Changing AC Power Specification, How to attach NH connector, Power Spec Antenna

Page 34

How to attach NH connector

HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE

NH connector wire

NH connector housing

1Insert NH connector wire into NH connector housing.

Shrink tubing

20mm

2Cut shrink tubing in 20 mm lengths and slip onto each wire.

Solder

 

3 Solder connector

4 Heat shrink

to signal cable.

tubing with solder-

 

ing iron.

Figure 2-14 How to attach NH connector

2.3 Changing AC Power Specification

For 100 VAC or 220 VAC power, add or delete jumper wires on the PTU Board and change the power fuses inside the display unit as shown in the table below accord- ing to ship’s mains. The figure below shows the location of the power fuses and the jumper wires on the PTU Board.

Table 2-2 Jumper wire setting on the PTU board, fuse rating and power specification

PCB

Power Spec.

Antenna

JP1

JP2

JP3

JP4

JP91

JP92

Power

rpm

Fuses

 

 

 

 

 

 

 

 

03P9245A

100/110/115 VAC

24 rpm

YES

YES

YES

NO

NO

NO

10A

03P9245C

100/110/115 VAC

42 rpm

YES

YES

YES

NO

YES

YES

 

03P9245D

220/230 VAC

24 rpm

NO

NO

NO

YES

NO

NO

5A

03P9245F

220/230 VAC

42 rpm

NO

NO

NO

YES

YES

YES

 

 

 

Jumper wire to use:

 

 

 

 

 

 

 

JP1: 0.8 dia. gilded wire

 

 

 

 

 

 

JP2, JP3, JP4, JP91, JP92: type ERD-S2TCOV

 

Fuse

03P9245

C11 C12

JP1

 

 

 

T1

 

JP2

 

JP92

 

 

 

 

 

 

 

 

U92

 

 

 

JP3

 

 

 

 

 

JP4

 

 

 

JP91

 

 

 

 

 

T21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTU Board

Figure 2-15 Display unit, inside view

2-12

Image 34
Contents Installation Manual Marine Radar FR-2125V 00080875300 Safety Instructions Use only the specified power cable System Configuration Standard Supply Name Type Code No Qty RemarksOptional Equipment Name Type Code No RemarksAntenna Unit Mounting considerationsBe sure to remove the guide pins Assembling the antenna unitFastening the antenna unit to the mounting platform Fastening the radiator to the radiator bracketAntenna unit, front view Before mounting the display unit Mounting procedureDisplay Unit Tabletop mountingStay Setting catch to hole in stay 12 How to dismount the PTU cover Console type mountingSeparate type control head kit Type OP03-157, Code No Display unit modification procedureSeparating the control head Name Type Qty Code No Remarks13 How to dismount covers 14 Clamp position 15 Detaching the control head Control head modification procedure PlateWiring between display unit and control head 17 Attaching the handle plate18 How to attach KB fixing plate Wiring Antenna unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 Power Switch in AC Powered Display Unit Power SwitchFabricating the AC power cable supplied DPYCY-3.5Fabricating the DC power cable CVV-S 8X2C, option CVV-S 8X2CCable fed from rear of display unit Default method Leading cables into the display unit Cable fed from outside display unit Cables fed from bottom of display unit for console mountConnections M4X8 2 pcsConnectors on the INT Board Input/Output SignalPower Spec Antenna Changing AC Power SpecificationHow to attach NH connector JP91 JP92Adjusting Video Signal Level Tuning InitializationAccessing Menus for Initialization and Adjustment Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangConfirming Magnetron Heater Voltage Magnetron heater voltage ratingInitial Setting Menus Press Radar Menu 0 0 0Initial SETTING2 menu Initial SETTING1 menuInitial SETTING3 menu Initial SETTING4 menu OWN Ship Information menuGyro Converter GC-8 Installation and connection of the Gyro Converter BoardName Type Qty Code No INT Board Gyro Converter Board J446 4P J465 6P 14P DIP switch, jumper wire settings Connection of external power supplyDefault setting Rotor voltage GyrocompassFrequency Remarks Stator voltageSW2-4 IntervalJP1 JP2 JP3 JP4 JP5 Setting the heading readout on the radar display SW1ARP Board ARP-26 Installation of the ARP boardARP board adjustment Name Type Qty Code No ARP Board 18P9002B 008-473-650Final check ARP Board 18P9002BRP Board RP-26 Table top/console typeFastening the M-card base assy. to the right arm cover Separate type control head Necessary parts RP-26-Z-2E Code no13 Display pedestal, front view 14 Display pedestal, front and top views Performance Monitor PM-30 Necessary parts PM-30 and OP03-150 Code noProcedure Alarm KitNecessary parts OP03-156 Code no 16 Display unit, inside view 03P9246A 008-487-440 AC-DC Conversion Kit03P9246C 008-493-700 Board Filter RDP-124 DC 008-492-460 Connection Connection of Rate-of-Turn SignalChecking operation Console Kit Necessary parts OP03-164 Code no20 How to fasten the edge guard Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page