Furuno FR-2125V ARP Board ARP-26, Installation of the ARP board, ARP board adjustment

Page 49

4.2 ARP Board ARP-26

The ARP Board ARP-26, which provides ARPA functions, is an optional circuit board which is accommodated in the display unit. Note that the ARP-26 is not available with the statute mile-type radar.

Necessary Parts: ARP-26-2E (008-485-500)

Name

Type

Qty

Code No.

 

 

 

 

ARP Board

18P9002B

1

008-473-650

 

 

 

 

Installation of the ARP board

1.Turn off the power. Remove the front panel from the display pedestal by unfas- tening four screws.

2.Set the ARP Board in the center slot of the PCB card case.

Display pedestal

Top: RP Board (Option)

Middle: ARP Board (Option)

Bottom: SPU Board

Figure 4-5 Display pedestal, inside view

3. Adjust the ARP Board referring to the procedure below.

ARP board adjustment

1.Turn the GAIN, A/C SEA and A/C RAIN controls fully counterclockwise (OFF). Transmit on the 12 nm range.

2.Connect a digital multimeter between TP7(+) and TP6(-) on the ARP Board.

4-8

Image 49
Contents Installation Manual Marine Radar FR-2125V 00080875300 Safety Instructions Use only the specified power cable System Configuration Name Type Code No Qty Remarks Standard SupplyName Type Code No Remarks Optional EquipmentMounting considerations Antenna UnitAssembling the antenna unit Be sure to remove the guide pinsFastening the radiator to the radiator bracket Fastening the antenna unit to the mounting platformAntenna unit, front view Display Unit Mounting procedureBefore mounting the display unit Tabletop mountingStay Setting catch to hole in stay Console type mounting 12 How to dismount the PTU coverSeparating the control head Display unit modification procedureSeparate type control head kit Type OP03-157, Code No Name Type Qty Code No Remarks13 How to dismount covers 14 Clamp position 15 Detaching the control head Plate Control head modification procedure17 Attaching the handle plate Wiring between display unit and control head18 How to attach KB fixing plate Wiring Antenna unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 Power Switch Power Switch in AC Powered Display UnitDPYCY-3.5 Fabricating the AC power cable suppliedCVV-S 8X2C Fabricating the DC power cable CVV-S 8X2C, optionLeading cables into the display unit Cable fed from rear of display unit Default methodCables fed from bottom of display unit for console mount Cable fed from outside display unitM4X8 2 pcs ConnectionsInput/Output Signal Connectors on the INT BoardHow to attach NH connector Changing AC Power SpecificationPower Spec Antenna JP91 JP92Accessing Menus for Initialization and Adjustment Tuning InitializationAdjusting Video Signal Level Restoring default settingsPicture appears Deviated counterclockwise Heading AlignmentSuppressing Main Bang Adjusting Sweep TimingMagnetron heater voltage rating Confirming Magnetron Heater VoltagePress Radar Menu 0 0 0 Initial Setting MenusInitial SETTING2 menu Initial SETTING1 menuInitial SETTING3 menu OWN Ship Information menu Initial SETTING4 menuGyro Converter GC-8 Installation and connection of the Gyro Converter BoardName Type Qty Code No INT Board Gyro Converter Board J446 4P J465 6P 14P DIP switch, jumper wire settings Connection of external power supplyDefault setting Frequency Remarks GyrocompassRotor voltage Stator voltageInterval SW2-4JP1 JP2 JP3 JP4 JP5 SW1 Setting the heading readout on the radar displayARP board adjustment Installation of the ARP boardARP Board ARP-26 Name Type Qty Code No ARP Board 18P9002B 008-473-650ARP Board 18P9002B Final checkTable top/console type RP Board RP-26Fastening the M-card base assy. to the right arm cover Necessary parts RP-26-Z-2E Code no Separate type control head13 Display pedestal, front view 14 Display pedestal, front and top views Necessary parts PM-30 and OP03-150 Code no Performance Monitor PM-30Procedure Alarm KitNecessary parts OP03-156 Code no 16 Display unit, inside view 03P9246A 008-487-440 AC-DC Conversion Kit03P9246C 008-493-700 Board Filter RDP-124 DC 008-492-460 Connection Connection of Rate-of-Turn SignalChecking operation Necessary parts OP03-164 Code no Console Kit20 How to fasten the edge guard Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page