Furuno FR-2125V Gyrocompass, Frequency Remarks, Rotor voltage, Stator voltage, Ratio SW1-1 SW1-3

Page 45

If the specifications of the gyrocompass differ from those mentioned above, change jumper wire and DIP switch settings on the GYRO CONVERTER Board as appro- priate. Settings may be changed according to gyrocompass specifications (page 4-4) or make and model of gyrocompass (page 4-5). For the location of DIP switches and jumper wires, see page 4-6.

Setting method 1: DIP switch settings by gyrocompass specifications

1) Gyrocompass type

Gyrocompass

SW

SW

SW

JP1

type

1-4

1-5

1-6

 

 

 

 

 

 

AC synchronous

OFF

OFF

OFF

#1, #2,

 

 

 

 

#3

 

 

 

 

 

DC synchronous

OFF

OFF

OFF

#2, #3,

 

 

 

 

#4

 

 

 

 

 

DC step

ON

OFF

OFF

#4, #5,

 

 

 

 

#6

 

 

 

 

 

Full-wave

OFF

ON

OFF

#4, #5,

pulsating current

 

 

 

#6

 

 

 

 

 

Half-wave

ON

ON

OFF

#4, #5,

pulsating current

 

 

 

#6

 

 

 

 

 

2) Frequency

Frequency

SW

SW

Remarks

 

1-7

1-8

 

 

 

 

 

50/60 Hz

OFF

OFF

AC synchronous

 

 

 

pulsating current

 

 

 

 

400 Hz

ON

OFF

AC synchronous

 

 

 

pulsating current

 

 

 

 

500 Hz

OFF

ON

AC synchronous

 

 

 

pulsating current

 

 

 

 

DC

ON

ON

DC synchronous

 

 

 

DC step

 

 

 

 

3)Rotor voltage

(between R1 & R2)

Rotor voltage

SW 2-1

JP3

 

 

 

 

 

20

V to 45

VAC

ON

#2

 

 

 

 

30 V to 70

VAC

OFF

#2

 

 

 

 

40 V to 90

VAC

ON

#1

 

 

 

 

60

V to 135 VAC

OFF

#1

 

 

 

 

 

4)Stator voltage (between S1 and S2)

Stator voltage

SW 2-2

SW 2-3

JP2

 

 

 

 

 

 

20

V to 45

VAC, or

ON

OFF

#2

20

V to 60

VDC

 

 

 

 

 

 

 

 

 

20

V to 45

VAC, or

OFF

OFF

#2

20

V to 60

VDC

 

 

 

 

 

 

 

40 V to 90 VAC

ON

OFF

#1

 

 

 

 

60 V to 135 VAC

OFF

OFF

#1

 

 

 

 

 

 

5) Ratio

Ratio

SW1-1

SW 1-2

SW1-3

 

 

 

 

360x

OFF

OFF

OFF

 

 

 

 

180x

ON

OFF

OFF

 

 

 

 

90X

OFF

ON

OFF

 

 

 

 

36X

ON

ON

OFF

 

 

 

 

6) Supply voltage

Supply voltage

JP4

JP5

 

 

 

 

 

20

V to 45

VAC, or

#2

#2

20

V to 60

VDC

 

 

 

 

 

 

30 V to 135

VAC, or

#1

#1

40

V to 100

VDC

 

 

 

 

 

 

 

 

4-4

Image 45
Contents Installation Manual Marine Radar FR-2125V 00080875300 Safety Instructions Use only the specified power cable System Configuration Name Type Code No Qty Remarks Standard SupplyName Type Code No Remarks Optional EquipmentMounting considerations Antenna UnitAssembling the antenna unit Be sure to remove the guide pinsFastening the radiator to the radiator bracket Fastening the antenna unit to the mounting platformAntenna unit, front view Display Unit Mounting procedureBefore mounting the display unit Tabletop mountingStay Setting catch to hole in stay Console type mounting 12 How to dismount the PTU coverSeparating the control head Display unit modification procedureSeparate type control head kit Type OP03-157, Code No Name Type Qty Code No Remarks13 How to dismount covers 14 Clamp position 15 Detaching the control head Plate Control head modification procedure17 Attaching the handle plate Wiring between display unit and control head18 How to attach KB fixing plate Wiring Antenna unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 Power Switch Power Switch in AC Powered Display UnitDPYCY-3.5 Fabricating the AC power cable suppliedCVV-S 8X2C Fabricating the DC power cable CVV-S 8X2C, optionLeading cables into the display unit Cable fed from rear of display unit Default methodCables fed from bottom of display unit for console mount Cable fed from outside display unitM4X8 2 pcs ConnectionsInput/Output Signal Connectors on the INT BoardHow to attach NH connector Changing AC Power SpecificationPower Spec Antenna JP91 JP92Accessing Menus for Initialization and Adjustment Tuning InitializationAdjusting Video Signal Level Restoring default settingsPicture appears Deviated counterclockwise Heading AlignmentSuppressing Main Bang Adjusting Sweep TimingMagnetron heater voltage rating Confirming Magnetron Heater VoltagePress Radar Menu 0 0 0 Initial Setting MenusInitial SETTING1 menu Initial SETTING2 menuInitial SETTING3 menu OWN Ship Information menu Initial SETTING4 menuInstallation and connection of the Gyro Converter Board Gyro Converter GC-8Name Type Qty Code No INT Board Gyro Converter Board J446 4P J465 6P 14P Connection of external power supply DIP switch, jumper wire settingsDefault setting Frequency Remarks GyrocompassRotor voltage Stator voltageInterval SW2-4JP1 JP2 JP3 JP4 JP5 SW1 Setting the heading readout on the radar displayARP board adjustment Installation of the ARP boardARP Board ARP-26 Name Type Qty Code No ARP Board 18P9002B 008-473-650ARP Board 18P9002B Final checkTable top/console type RP Board RP-26Fastening the M-card base assy. to the right arm cover Necessary parts RP-26-Z-2E Code no Separate type control head13 Display pedestal, front view 14 Display pedestal, front and top views Necessary parts PM-30 and OP03-150 Code no Performance Monitor PM-30Alarm Kit ProcedureNecessary parts OP03-156 Code no 16 Display unit, inside view AC-DC Conversion Kit 03P9246A 008-487-44003P9246C 008-493-700 Board Filter RDP-124 DC 008-492-460 Connection of Rate-of-Turn Signal ConnectionChecking operation Necessary parts OP03-164 Code no Console Kit20 How to fasten the edge guard Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page