Flush mounting
Use the optional flush mount kit
Contents of flush mount kit for RCU-014/015/016
Name | Type | Qty |
|
|
|
Mounting plate | 4 | |
|
|
|
Hex bolt | M5 | 4 |
|
|
|
Wing screw | M5×40 | 4 |
|
|
|
Pan head screw | M4×12 | 4 |
|
|
|
1. Prepare a cutout in the mounting location as shown in the figure below.
170±2
176±2
388±2
150±2
Flush mount cutout for
2.Set the control unit to the cutout.
3.From the rear side, attach the mounting plate to the control unit with four screws.
4.Screw the wing screw to each mounting plate and then insert hex bolt to each wing screw.
5.Fasten each wing screw and then fasten the hex nuts as shown in the figure below.
#70 | 92 (P) | #70 | |
53 | |||
| |||
|
| 171 | |
| Note: P | < | |
| =10 |
53 | 86 (P) |
# Minimum recommended service space
To change location of cable entrance, see page
Flush mount mounting dimensions for control unit