Furuno FAR-2157-BB, FAR-2157-D installation manual How to adjust the overvoltage detection circuit

Page 41

J105 J106

(P)HV

PWR board

J104

 

J103

R21

 

(OVER)

 

P108/J108

J101

AC FIL

 

8 7 6 5 4 3 2 1

 

Jumper connector (VH8P)

Processor unit, inside view

How to adjust the overvoltage detection circuit:

1.Add or remove the jumper connector P108 as appropriate and change the fuse, referring to the table on the previous page for details.

2.On the PWR board, set R21 fully clockwise.

3.Connect a variable transformer between ship's mains and the input power terminal board TB- 1 in the processor unit.

4.Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows:

For 100 VAC set: 144 VAC

For 220 VAC set: 288 VAC

5.Turn on the radar and rotate R21 counterclockwise gradually until the overvoltage detection cir- cuit activates (i.e., power supply cuts off).

6.Lower the output voltage of the variable transformer and confirm that the radar automatically turns on with a voltage lower than 142 VAC or 284 VAC.

7.Gradually increase the output voltage of the variable transformer and confirm that the over- voltage detection circuit activates at 144 V or 288 VAC of the variable transformer output.

8.Assemble and connect the processor unit.

2-17

Image 41
Contents Installation manual 00014869214 Safety Instructions Use only the specified power cables Iii System ConfigurationOptional equipment Standard supplyName Type Code No Qty Remarks Name TypeDVI-RGB Name Type Code No RemarksThis page is intentionally left blank Mounting considerations Antenna UnitSiting MountingAssembling the antenna unit How to coat waveguide flange with silicon rubberName Type Qty How to attach hoisting ropes to antenna unit How to hoist antenna unitFastening antenna unit to the mounting platform Coat with anticorrosive sealant How to mount the antenna unitFlush mounting Mounting procedureMonitor Unit Desktop mounting Contents of desktop mounting kit FP03-09820Attaching hand grips Fixing with KB keyboard fixing plate Control UnitFixing without KB fixing plate Mounting dimensions for control unit RCU-014Mounting dimensions for control unit RCU-015/RCU-016 Contents of flush mount kit for RCU-014/015/016 Control unit RCU-014, inside view Connecting RCU-016 in series with RCU-014Changing cable entrance on control unit RCU-015/RCU-016 Changing the cable entrance on control unit RCU-015/RCU-016Processor Unit Mounting dimensions for processor unitMounting dimensions for power supply unit Power Supply UnitWiring Overview WiringAntenna unit, front view Fabricating signal cable RW-9600Fabricating signal cable RW-9600 TB801 PCB 03P9436 Cable gland for signal cable RW-9600 Procedure How to wire Wago connectorHow to fasten coaxial conductor Passing flat washer, etc. onto HV cable Fabricating HV cable TYPCY-1.5 and power cable TYPCY-2.5How to fabricate HV cable TYPCY-1.5 Passing flat washer, etc. onto power cable How to fabricate power cable TYPCY-2.5Fabricating power cable DPYC-2.5 Fabricating the power cable DPYC-2.5Fabricating power cable DPYC-2.5 Processor unit, rear view Connection of cablesCable XH10P-W-6P L=20/30M Cable XH10P-W-5P-A L=10/20/30MLocation of connectors inside the processor unit Location of connectorsPower cable TPYC-1.5 Signal cable RW-9600 Between antenna unit and processor unitPort Conventional remote display FAR-2157 Connection of Sub-displayTerminal TB1 cable DPYC-2.5 Power supply unit, inside viewFabricating cable connected to terminal TB1, TB2, TB3 Armor Power supply Fuse Jumper connector P108 Changing AC Power SpecificationProcessor unit Processor unit, inside viewHow to adjust the overvoltage detection circuit Power Fuse Jumper connector P8 Power supply unitInitializing Tuning AdjustmentsHeading alignment Heading AlignmentFor Control Unit RCU-015 For Control Unit RCU-014Initialize menu Echo ADJ menuHow to access the Initialize Menu with Control Unit RCU-015 Examples of correct and incorrect sweep timings Adjusting Sweep TimingSuppressing Main Bang Echo menu setting Other SettingsANT SW and ANT Stopped Scanner menuBlind Sector 1 and Blind Sector On Time and TX Time Installation menuRadar no and Radar Posn GPS 1 ANT Posn and GPS 2 ANT Posn OWN Ship Info menuLENGTH/WIDTH, Scanner Posn and SUB Scanner Posn ARP-related menus Arpa Preset menuARP W/O Gyro Not shown on IMO radar ANT Select Other menu Other menuEAV w/o Gyro This page intentionally left blank Gyro Converter GC-10 Installing the Gyro Converter boardFixing Gyro Converter board inside the processor unit Wiring Wago connector Connecting connector assemblies inside processor unitAttaching plastic cover for Gyro Converter board DIP switch, jumper wire settings Connection of external power supplyDefault setting Connection of external power supply to Gyro Converter boardJP1 JP1 JP2 JP3 JP4 JP5 Setting method 2 by make and model of gyrocompassGyro Converter board 64P1106HDG menu Setting the heading readout on the radar displayMemory Card Interface Unit Flush mounting dimensions for memory card interface unitDesktop mount ConnectionsOne memory card if unit and one processor unit One memory card if unit and multiple processor unitsType Code No Contents DVI-RGB Conversion Kit How to wire the DVI-RBG conversion boardProcessor unit bottom chassis Processor unit, side viewConnecting wires to the housing DVI-RGB BNC Connector ConverterOutput Data Specifications Contents RemarksInput IEC 61162 output sentence IEC 61162 input sentence and prioritySentence and order of priority SentenceList #  70+6 000-157-497-10 工事材料表 000-155-826-10 Packing List AC100V 付属品表 03GL-X-9506 . CU-200-FAR GC-10-2 GC-10 $40# Page Page May 1707 R.Esumi Sep/2010 Y.NISHIYAMA Page Jan.1808 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Page Page Page Page Page Page Page Page Page Marine RADAR/ARPA